INSTALLATION
INSTALL SUCTION LINE TO PUMP HEAD
1. Uncoil the suction/discharge line. Use outside of solution tank as a guide to cut proper length of suction line
ensuring it will be 2-3" above the bottom of solution tank.
Allow sufficient slack to avoid kinks and stress cracks. Always make a clean square cut to assure that the
suction line is burr free. Normal maintenance requires trimming.
Suction lines that extend to the bottom of the tank can result in debris pickup leading to clogged injectors
and possible tube failure.
2. Make connections.
S30 Models
1/4"
Slide line through connecting nut and ferrule and insert into tube fitting until it stops. Firmly hold
the tube fitting and finger tighten nut.
3/8"
Finger tighten the adapter onto the tube fitting. Slide line through connecting nut and insert into
adapter until it stops. Firmly hold adapter and finger tighten nut. Then wrench tighten nut one
additional half turn. If leak occurs, gradually tighten nut as required.
S40 & S50 Models
3/8"
Slide line through connecting nut and insert into the tube fitting until it stops. Firmly hold the tube fitting
and finger tighten nut. Then wrench tighten nut one additional half turn. If leak occurs, gradually tighten
nut as required.
3. Finger tighten nut to the threaded tube fitting while holding the tube fitting.
Over tightening the ferrule and nut may result in damaged fittings, crushed ferrules, and air pick up.
DO NOT use thread seal tape on pump tube connections.
Ferrule
Connecting Nut
Discharge Line
Suction Line
S Series FW 4.01.02 US and Canada 800.683.2378, International 904.641.1666 www.stenner.com
continued
NOTE: Beveled ends of ferrules face pump.
Tubing should bottom into all fittings.
Finger tighten 1/4" nut
DO NOT use thread seal tape on pump tube threads.
82