CONTROL MODES MENU
CYCLE TIMER
Operator can configure a run time and off time cycle for the pump to continuously repeat.
NAVIGATION
Moves up in a menu, toggles
between options, or increase a value
Holding the
or
button causes the numbers to change rapidly.
Control Mode
- 7 Day Timer
- PPM Feed
- Cycle Timer
S Series FW 4.01.02 US and Canada 800.683.2378, International 904.641.1666 www.stenner.com
continued
Moves down in a menu, toggles
between options, or decreases a value
Run Time per Cycle
_ _ _20 second(s)
adjust
Total Cycle Time
_ _ _ 21 second(s)
adjust
Pump Speed
100 %
adjust
To Main Menu
52
Moves one step back in
a menu, when permitted
Set the run time (the amount of time the
pump should run per cycle). The run time
can be set from 20 to 99,999 seconds.
set
Set the total cycle time (total cycle time
is the pump run time plus the pump off
time). The total cycle time can be set
from 21 to 99,999 seconds.
set
Set the pump speed percent the pump will run.
Once these settings have been entered, the
display will return to the Main Menu.
set
Sets a value in a menu