5.4.5 Arm connection cable: connector J2
ATTENTION
The connector must be wired after the arm connection cables have been positioned in the
machine.
Connect the individual cable wires to the numbered Phoenix 4153612201 screw terminals, as indicated
on the connector and in the following tables.
Connect the finished cable to the E32A SSR interface.
E32A
Figure 5-11. Wiring the 4153612201 PHOENIX flying connector to be inserted in J2
Connector J2
PIN N° IN/OUT NAME
1
IN
TOUCH PROBE -
2
IN
TOUCH PROBE +
3
IN
ARM STATUS
4
OUT
LED STATUS
5
OUT
GNDM
6
OUT
+12VDC
7
-
-
8
IN
PROX UP
9
IN
PROX DOWN
10
OUT
GNDT
11
OUT
MOTOR+
12
OUT
MOTOR-
MIDA TOOL EYE-ELECTRIC
80
BLACK/MOTOR-
RED/MOTOR+
YELLOW/PROX DOWN
GREEN/PROX UP
BROWN (+12V) + GREY-PINK
BLUE/GNDM (SINK)
GREY/LED STATUS
RED-BLUE/ARM STATUS
VIOLET/TOUCH PROBE+
WHITE/TOUCH PROBE-
J2
DESCRIPTION
Probe status signals
Probe status signals
Status signal indicating the arm type in use
Dual colour arm LED control
Negative of arm Power supply
Positive of arm Power supply
-
Indicates that the arm is at rest.
Indicates that the arm is in the measurement position.
Connected to PE (protective earth) inside to the E32A
Motor command
Motor command
12
1
ARM
CABLE

Publicidad