5.5.3 Selecting SINK/SOURCE operating mode (JP1)
E32A can be programmed so that the J1 connector outputs and inputs operate in the SINK or SOURCE
mode. To program the operating modes install the jumpers JP1 on the circuit board as indicated in the
Figure 5-16).
A
Sink
Mode
B (*)
Source
Mode
(*)
Note: Default condition
Figure 5-16. Selecting SINK/SOURCE operating mode.
5.5.4 Manual Mida Tool EYE management with Electrical E32A
The Electrical E32A SSR can be forced to emulate the Manual E32A SSR. Use the following connection
diagram, depending on the sink/source mode selected for the E32A SSR.
SOURCE programmed E32A SSR
Connect pins 18 (Arc) and 19 (Mrc) to the +24Vdc
supply. Connect as shown in the figure.
Figure 5-17. Manual application management with E32A
MIDA TOOL EYE-ELECTRIC
84
SINK programmed E32A SSR
Connect pins 18 (Arc) and 19 (Mrc) to the GND 0 V
supply. Connect as shown in the figure.