5.5 FUNCTION
5.5.1 Inhibit function
The Inhibit function allows you to disable touch signal processing. If set to TRUE (logic 1) the touch probe is
always not deflected (see CASES 1 and 2 in Figure 5-13).
TRUE
FALSE
Figure 5-13. Inhibit function cycle diagram.
N.B.: Ts = 44msec. nominal ± 30%;
N.B.
i
Once the operating logic mode (TRUE/FALSE) has been identified, check on the machine if you
need to work in SOURCE or SINK mode:
TRUE  high voltage
SOURCE MODE:
FALSE low voltage
The interface default setting is operation in SOURCE mode (see section 5.5.3 "Selecting SINK/SOURCE
operating mode (JP1)").
MIDA TOOL EYE-ELECTRIC
82
CASE 1: INHIBIT=FALSE
TRUE
FALSE
CASE 2: INHIBIT=TRUE
Td = 6.6 msec. nominal ± 10%.
TRUE  low voltage
SINK MODE:
FALSE high voltage