Precautions
Warning:
If you neglect these precautions, it might cause personal injury
such as electric shock, fire or damage to the product.
1. This product is not a home appliance equipment. It is only applicable for hospitals and
dental clinics. The use of the product must comply with the requirements of the relevant
operating specifications and relevant laws and regulations of the medical department.
The user must be a professionally trained and qualified dentist or technician. Ade-
quate protection (such as goggles, mask, etc.) should be equipped during operation to
prevent cross-infection.
2.
Please use an independent power outlet with protective grounding. Do not unplug the
power cord with wet hands.
3. Please fully insert the power plug of the device into the power socket, please do not use
other power source other than the specified voltage.
4. Do not damage, modify, pull, bend or twist the power cord excessively, and do not place
heavy objects on the power cord.
5. After using the machine, turn off the power switch and pull out the power plug.
6. When the equipment recovers after power off, please await the equipment to be stable
before stepping on the pedal. The operator should release the pedal in time when the
power is off.
7. Please do not place the product on an unstable workbench, such as a swaying table,
an inclined surface, or a location subject to vibration.
8. This equipment is a reusable product. Keep the equipment clean before and after use.
Before each use, the handpieces, tips, torque wrench etc. must be disinfected and ste-
rilized. It is suggested to disinfect and sterilize according to the recommended method
in Chapter 5 of this manual.
9. Do not knock or scrape the handpiece. Do not pull the cable forcefully during the use
of the equipment to avoid damages.
10. Do not bend or polish the tips. The tips must be screwed to the handpiece with a torque
wrench, and water spray must be generated during operation.
11. Before each operation, you should work outside the patient's mouth for more than 10
seconds under the condition of water to drain the water in the pipeline at the back of
the handpiece
12. When the tip is damaged or worn out, the vibration intensity might decrease. The ope-
rator should replace a new tip in time according to the clinical situation. It is not recom-
mended to use the tip after the abrasion of tip exceed 2mm or more. You can use the tip
comparison indicator to check. If the length is out of the first line, the power remains the
same; if it is between the first and second line, the power would decreased to 80%; if it
reaches or surpass the second line, the power would drop massively, on the occasion,
replacement of tip is recommended.
13. Do not screw or unscrew the tip while stepping on the foot switch, or when the machine
is on working.
14. The inner thread of the tip manufactured by certain manufacturers are rough, rusty
and might break the thread system, which will cause irreparable damage to the scaler.
Please use corresponding tips of Clean & White brand.
15. Choose the appropriate power according to different types of tips. See Annex Tip power
chart There are recommended power and water volume for different types of tip in the
system. You can double -click the current mode to choose the tip.
16. Do not use unclean water
17. Improper cleaning and treatment of titanium implants, porcelain restorations, etc. can
easily cause loosening of the adhesive, cracking of the porcelain restorations, or even
cracking of the porcelain. The cleaning or treatment of the oral cavity should be care-
fully considered.
18. Noise will be generated during the scaling process. Those who are sensitive to noise
can wear earplugs by themselves.
19. We will be responsible for the safety only when the maintenance, repair and modifica-
tion of the machine are carried out by the company or its authorized distributors, the
replacement parts are from the company, and the operation is on the basis of instruc-
tion manual.
20. This equipment has electromagnetic interference. Do not use it around electronic sur-
gery, and be cautious in an environment with strong electromagnetic interference when
using this equipment.
21. This equipment does not contain toxic or hazardous substances, and it can be dis-
carded in accordance with the relevant laws and regulations on discarded medical
devices.
22. Do not step on the foot pedal when the cable of the air polish handpiece is removed
from the main unit.
23. Before using the ultrasonic handpiece, please make sure that the cable of the air polish
handpiece is correctly placed on the handle bracket; similarly, before using the air poli-
sh handpiece, please make sure that the cable of the ultrasonic handpiece is correctly
placed on the ultrasonic handle bracket.
24. The tip must be tightened.
25. The air polishing handpiece nozzle should not be aimed at people.
26. There might be injury if the powder accidentally sprays into the eyes. We strongly
recommend that all personnel (doctors, nurses, patients) wear goggles during air poli-
shing treatment.
27. Please do not unload the powder tank when stepping on the pedal or when the ma-
chine is working.
28. Before replacing the air polishing handpiece or the nozzle, please use a syringe to blow
the moisture at the joints at both ends (especially the gas interface) to prevent moisture
from entering the gas path and avoid clogging of the powder in the pipeline.
29. The device must not be used in MRI environment for the device is easily affected by the
electromagnetic emission and would not work or work normally.
30. When you meet circumstances where the main unit expires, the misuses lead to the
short circuit of the circuit board or accidentally dropping the device results in the da-
mage of components, the device should no longer be reused.
Contraindications
1. The hemophilia patient is forbidden to use this equipment
2. The patients or the doctors with heart pacemaker are forbidden to use this equipment.
_R0_XPOWER ablatore_bug_6lingue.indd 3
_R0_XPOWER ablatore_bug_6lingue.indd 3
3. Heart disease patients, pregnant women and children should be cautious to use the
equipment.
4. Patients with respiratory diseases such as asthma and chronic bronchitis are not al-
lowed to use this device.
Symbol Instruction
Symbol
Implication
Trademark
Consult instructions for use
Protective earth (ground)
Caution
Anti-drip equipment
Sterilizable in a steam
sterilizer (autoclave)
at 134°C
Recovery
Manufacturer
For indoor use only
Date of manufacture
Type B applied part
Alternating current
ON (power)
OFF (power)
ON/OFF
ON/OFF
Functional earth
Foot switch
Forward
Guilin Refine Medical Instrument Co., Ltd. is a high-tech enterprise integrating R&D, produc-
tion and sales of dental products, with a complete quality assurance system.
1 Product introduction
1.1 Brief introduction
Xpower Ultrasonic Scaler & Air Polisher combines ultrasound scaler and air polishing scaler.
The main features are:
1) According to the selected handpiece, automatically switch the working mode.
2) Touch LCD screen.
3) Special chemical solutions such as hydrogen peroxide, sodium hypochlorite and
chlorhexidine can be used to improve the clinical treatment effect.
4) LED handpiece enables convenient Clinical operation.
5) The automatic frequency tracking system for the best working condition, which brings
more stable performance of device.
6) Detachable ultrasonic handpiece and air polishing handpiece can be sterilized under high
temperature of 134 and high pressure of 0.22MPa.
1.2 Model: Xpower
1.3 Intended use
This product includes an ultrasonic system and an air polish system. The ultrasonic system
is used for periodontal treatment in oral clinical treatment to remove tartar and plaque, root
canals cleaning; Air polish system is used to remove plaque and pigment, it can also used
for implants maintenance.
EN
Symbol
Implication
Temperature limit:
-20°C - +55°C
Atmospheric pressure
limitation: 70kPa-106kPa
Humidity limitation:
10%-93%
Keep dry
Fragile, handle with care
Waste electrical and
electronic equipment
Boost mode
Anhydrous mode
Clean mode
CE marking
with identification number
of the Notified Body
Authorized representative
in the European Community
Serial number
Medical device
Authorized representative
in the United Kingdom
Batch number
Unique device identifier
Authorized representative
in the United Kingdom
| 3