14
Auxiliary water
jet outlet
15
Working channel
outlet
16
Camera
17
Light source (LED)
18
Suction connector
19
Auxiliary water jet
connector
20
Endoscope
connector
21
Insufflation/rinsing
connector
22
Release button
23
Umbilical cord
24
Spare suction
valve
2.2. Device compatibility
The endoscope can be used in conjunction with:
Ambu® aBox™ 2�
Insufflators for endoscopic gastrointestinal procedures with a constant flow of medical
grade gas with a maximum supply pressure of 80 kPa (12 psi)�
Standard insufflation/rinsing fluid management tubing sets compatible with Olympus
endoscopes including sterile water bottle�
Vacuum source to provide aspiration with a maximum vacuum of -76 kPa (-11 psi�)
Standard flexible suction tubes�
Irrespective of the chosen fluid management system, the suction container assembly
used must feature overflow protection in order to prevent fluids from entering the system;
this feature is commonly referred to as "self-sealing", "shut-off-filter" or similar�
Gastrointestinal endotherapy accessories specified to be compatible with a working channel
with an inner diameter (ID) of 2�8 mm/8�4 Fr or less for aScope Gastro and with an ID of
4�2 mm/12�6 Fr or less for aScope Gastro Large�
Gastrointestinal endotherapy accessories specified to be compatible with a distal end
with an outer diameter (OD) of 9�9 mm/29�7 Fr for aScope Gastro and with an OD of
11�5 mm/34�5 Fr for aScope Gastro Large�
There is no guarantee that endotherapy accessories selected using only this minimum working
channel size and/or outer diameter of distal end will be compatible with the endoscope�
Medical-grade water-based lubricants, iodine-based contrast agents, lipiodol,
hemostatic agents, lifting agents, antifoaming agents, tattoo for permanent staining,
and dyes for vital staining�
Sterile water�
HF electrosurgical equipment fulfilling IEC 60601-2-2� The application of high-frequency
current may interfere with the endoscopic image� This does not indicate a malfunction�
Auxiliary irrigation pump for endoscopic gastrointestinal procedures with a Luer connector�
The auxiliary water jet system is used for endoscopic
irrigation of the patient's upper GI tract�
This is the opening of the working channel at
the distal end�
Enables visualization of the upper GI tract�
Enables illumination of the upper GI tract�
Connects the endoscope to the suction tube�
Connects the endoscope to the irrigation tube
of the irrigation pump�
The auxiliary water jet connector has an integrated
one-way valve to reduce the risk of backflow�
Connects the endoscope to the grey connector
port of the displaying unit�
Ancillary equipment for suction, insufflation,
lens rinsing and irrigation can be attached to
the endoscope connector�
Connects the endoscope to the sterile water bottle
to enable insufflation and lens rinsing�
Press the button when disconnecting
the endoscope from the displaying unit�
Connects the control section with
the endoscope connector�
Can be used to replace the existing suction valve
in case of blockage or damage�
9