Descargar Imprimir esta página

Schulz Control I Manual De Instrucciones página 204

Ocultar thumbs Ver también para Control I:

Publicidad

Idiomas disponibles

Idiomas disponibles

An edit window will appear. Use the buttons
Press
to confirm the selected value,
the parameter text.
8.5 MENU MAP
Obs: Screens may vary depending on the setup that was performed.
Press ENTER to access the sub-menus for each item (Ex.: P02.10.01).
P00 – Home
P01 – Hour Meters
01 Active alarm
01 Total hours
02 Control mode
02 HRS load/relief
03 P00.03 (configurable)
03 Hours under load
04 P00.04 (configurable)
04 Hours in relief
05 P00.05 (configurable)
05 Hours stopped
06 Output temperature
06 Air filter maint. (configurable)
07 Output pressure
07 Oil filter maint. (configurable)
08 Internal pressure
08 Separator maint. (configurable)
09 Differential pressure
09 MTR grease maint. (configurable)
11 Main MTR curr
10 Check oil (configurável)
12 MTR fan curr
11 Maint. hours (configurable)
13 Time
12 Maint. hours (configurable)
14 Date
13 Maint. hours (configurable)
15 DST
14 Weekly manutenance
16 GCI Sequence
15 Anual manutenance
17 Seq. Cycle - hours
16 Biannual maintenance
18 XPM GCI pressure
P09 – Access
P10 – Settings EQUIP 1
01 Standard User
01 Control mode*
02 Administrator
02 Perm load strengh
03 User 1
04 Load pressure
04 User 2
05 Relief pressure
05 User 3
06 Operating period
06 User 4
07 Relief period
07 User 5
08 PD radiador
08 User 6
09 RS485: 1 SETUP
09 User 7
10 RS485: 2 SETUP
10 User 8
12 Starting source*
11 User 9
13 Load source*
12 User 10
14 Language
15 Time
16 Time format
17 DST
18 Date
19 Date format
20 Backlight
21 Pressure unit
22 Temperature unit
23 Pres target VSD
7.5
C o n t r o l m o d e
Va r i a b l e s p e e d
Va r i a b l e s p e e d
Figure 8.4.4
to select one of the possible options. Hold the button
to exit the edit window. With the active edit window hold down
Table 8.5.1 - Read-only menu
P02 – Usage
P03 – Errors list
01 Equip Status
01 Error 1
02 HRS load/relief
03 Part MTR last HR
50 Error 50
04 Part MTR last 24h
05 Load freq.
06 Load % last hour
07 Load % last 24h
08 Load time last HR
09 Load time last 24h
10 Average VSD RPM
Table 8.5.2 - Reading and Edit Menu with keyboard or ECO card - 1
P11 – Settings EQUIP 2
01 Transition Y/D
02 MTR oper min time
03 Load time
04 Reload time
05 Relief time
06 Min. stop time
07 Cooling time
08 Auto switch on
09 Open purge
10 Purge interv
11 Purge in relief
12 Starts by hour
13 Press Dif delay
14 Maintenance hours 1
15 Maintenance hours 2
16 Maintenance hours 3
17 Maintenance hours 4
18 Maintenance hours 5
19 Maintenance hours 6
20 Maintenance hours 7
21 Maintenance hours 8
22 Weekly maintenance
23 Annual maintenance
24 Biannual maintenance
204
bar
O f f
7. 5 b a r
7. 5 b a r
P04 – Event List
01 Event 1
-
200 Event 200
P12 – Settings EQUIP 3
P13 – Settings FLEX
01 Reset parameters*
01 VSD control mode
02 Save as default*
02 Pres target VSD*
03 Use custom SEN*
03 MAX VSD Speed*
04 Output pres range*
04 MIN VSD Speed*
05 Int pres range*
05 OPT VSD Speed*
06 Reset REG errors
06 VSD Relief Speed
07 Reset REG event
07 VSD RPM Speed
08 VSD Output CURR*
08 HRS total STR
09 Adjust load HRS
09 Const P VSD*
10 Adjust relief HRS
10 Const I VSD*
11 Adjust stopped HRS
11 Const D VSD*
12 Sensor AI3 type
12 VSD Speed %*
13 Sensor AI5 type
13 VSD max acl ramp*
14 Int pres sens
14 Line lim speed
15 GCI available
25 Avoid Hz 1 MIN
16 P GCI sensor range
17 Temp fan on
18 Temp fan off
19 Fan on min time
20 Opening screen
21 P00.03 SETUP
22 P00.04 SETUP
23 P00.05 SETUP
24 Warning alarm
27 Dryer type
28 Output Dryer off
29 Time Dryer on
30 Max no. starts
31 Stop alarm started
32 Ind. start
33 Check start delay
to increase the navigation speed.
to toggle between the value and
P08 – Message Codes
Refer to this manual
-
P14 – Motor Protection
01 Main MTR protection
02 Protec MTR fan
03 Main MTR Rated Curr
04 Main MTR start
05 ROT BLOC main MTR
06 DES phase main MTR
07 MTR Fan rated Curr
08 Start MTR Fan

Publicidad

loading

Este manual también es adecuado para:

Control iiControl iiiControl net