P16.05
P16.06
P16.07
P16.08
P16.09
P16.09.01
P16.09.02
P16.09.03
Warning alarm
P16.09.04
P16.09.05
P16.09.06
P16.10
P16.11
P16.12
P16.13*
P16.14*
Press ENTER to access the sub-menus - *Editable only when the machine is stopped.
Reading and editing with keyboard or ECO card
It is recommended to set this parameter to control the maintenance frequency for checking and/or replacing oil.
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set from 0 to 10,000 hours (100-hour pitch). The default value is 2,000
Check oil
hours.
Press 'ENTER' again. The set value is stored in memory and the browser returns to P16.05.
Note: you need to enable the parameter in menu P11 - equipment settings.
Programmable. Used to control maintenance frequency (miscellaneous use).
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set from 0 to 10,000 hours (100-hour pitch). The default value is 2,000
Maintenance hours
hours.
Press 'ENTER' again. The set value is stored in memory and the browser returns to P16.06.
Note: you need to enable the parameter in menu P11 - equipment settings.
Programmable. Used to control maintenance frequency (miscellaneous use).
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set from 0 to 10,000 hours (100-hour pitch). The default value is 2,000
Maintenance hours
hours.
Press 'ENTER' again. The set value is stored in memory and the browser returns to P16.07.
Note: you need to enable the parameter in menu P11 - equipment settings.
Programmable. Used to control maintenance frequency (miscellaneous use).
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set from 0 to 10,000 hours (100-hour pitch). The default value is 2,000
Maintenance hours
hours.
Press 'ENTER' again. The set value is stored in memory and the browser returns to P16.08.
Note: you need to enable the parameter in menu P11 - equipment settings.
Weekly maintenance warning.
Manut semanal
Press 'ENTER' to access sub-menu P16.09 ##.
Note: you need to enable the parameter in menu P11 - equipment settings.
Enables automatic scheduling for the next service (weekly).
AUTO SCHEDULING
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to select 'YES'. Press 'ENTER' again to confirm.
Note: automatic scheduling adds 7 calendar days to the value set at P16.09.02 ~ P16.09.05.
Manual "year" setup for next maintenance.
Year
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set the 'year'. Press 'ENTER' again. The set value is stored in memory
and the browser returns to P16.09.02.
Manual "month" setup for next maintenance.
Month
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set the 'month'. Press 'ENTER' again. The set value is stored in
memory and the browser returns to P16.09.03
Manual "day" setup for next maintenance.
Day
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set the 'day'. Press 'ENTER' again. The set value is stored in memory
and the browser returns to P16.09.04.
Time
Manual "time" setup for next maintenance.
Press 'ENTER'. The set value is stored in memory and the browser returns to P16.09.
Saves changes
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set the 'time'. Press 'ENTER' again. The set value is stored in memory
and the browser returns to P16.09.05.
Annual maintenance warning.
Press 'ENTER' to access submenu P16.10 ##.
Annual maintenance
Note1: you need to enable the parameter in menu P11 - equipment settings.
Note2: follow the sequence of year, month, day, and time settings described above.
Bi-annual maintenance warning.
Press 'ENTER' to access submenu P16.11 ##.
Bi-annual maintenance
Note1: you need to enable the parameter in menu P11 - equipment settings.
Note2: follow the sequence of year, month, day, and time settings described above.
Compressor outlet air over-temperature warning.
Analog type (see menu P12.12):
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set between 'OFF', 70° C and 240° C (or other selected temperature
Output temperature
unit), unit pitch. Press 'ENTER' again. The set value is stored in memory and the browser returns to P16.12.
Digital type (see menu P12.12):
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set between 'OFF' and 'ON'. Press ENTER again. The set value is
stored in memory and the browser returns to P16.12.
Compressor outlet air over-pressure warning.
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set between 'OFF' and the maximum permissible pressure desired
OUTPUT PRESSURE
(pitch 0.1BAR). Press 'ENTER' again. The set value is stored in memory and the browser returns to P16.13.
Note1: minimum configurable value is 0.1BAR above the relief pressure.
Note2: maximum configurable value is 0.1BAR below the compressor immediate stop pressure.
High internal pressure warning. Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set between 'OFF' and the maximum
allowable value (0.1 bar pitch). Press 'ENTER' again. The set value is stored in memory and the browser returns to the
previous menu.
Internal pressure
Note: minimum allowable value is 0.1 bar (or other pressure unit) above the high output pressure warning
value (P16.13).
Note: maximum permitted value is 0.1bar (or other pressure unit) below the internal pressure error value
(P17.04).
219