Main motor starting sequence
07
The start of the main motor is commonly associated with the start time of the main motor that precedes any equipment load status. For
example: in a constant speed compressor, this is the star/delta start time added to the equipment load delay time.
Relief operation, load delay time
08
When set, the load delay time precedes the first time the compressor goes into load, after the main motor starts (see P11.02).
09
On-load operation
Funcionamento em alívio, tempo de recarga
10
Quando configurado, o tempo de recarga precede o retorno do funcionamento em carga do equipamento (veja: P11.03)
Relief operation, reload time
11
Operation in relief condition is usually associated with managing the number of main motor starts per hour.
Relief operation, stoppage time
Relief operation in stoppage time condition is usually associated with a main motor stoppage and the return of the equipment to ready-to-
12
-start condition. The stoppage time value must be enough for
the compressor to perform all of its mechanical stoppage functions that must be performed before the main motor stops. After this period,
the equipment will return to ready to start status (see: P11.05).
10. LIST OF ABBREVIATIONS
Abbreviation
Text
ACTIVE
Active or enabled
ADCT
Compressor unit discharge temperature
ADV
Automatic purge valve
AI
Analog input
AIR
Air
ALM
Alarm or alarm message
AMB
Environment
ANAL
Analog
AO
Analog output
APR
April
AUG
August
AUTO
Automatic
AVAIL
Available
BRG
Bearing (s)
BELT
Belt
BIN
Binary
BUVV
Butterfly valve
CAB
Cabinet
CBV
Bypass valve
CFG
Settings
CLK
Clock
CLR
Heat exchanger
CNDS
Condensed
COOL
Cooling
COMP
Compressor
COMMS
Communication
COP
Change Point
CO BK
Continuous brake
CO
Compressor output
CONFIG
Setup or settings
CONT
Contactor
CORR
Correction
CT
Current Sensor
CURR
Current
CW
Cooling water
CWT
Cooling water temperature
DAY
Day
Abbreviation
Text
MANUF
Manufacturer
MAR
March
MAX
Maximum
MAY
May
MDL
Model
META
Manager
MIN
Minimal
MIN'S
Minutes
MMT
Measurement
MON
Monday
MOD
Modulation
MOTOR
Motor
MOPS
Motor overload protection switch
MPA
Mega Pascal
MPV
Minimum pressure valve
MTH
Month (s)
NC
Normally closed
NO
Normally open
NOM
Rated
NUM
Number
OCT
October
OIL
Oil
OK
Safe or normal
OVLD
Overload
OPT
Optimal
OR
Operating Range
OP CRT
Open circuit
OS
Oil separator
OSD
On screen
OUT
Output
P#
Parameter 0, 1, 2, ...
PARA
Parameter
PD
Equipment discharge
PERMS
Allowed
PLC
Preprogrammed logic controller
PR
Pressure
PRESS
Pressure
233