Press ENTER to access the sub-menus - *Editable only when the machine is stopped.
Reading and editing with keyboard or ECO card
8.10 DIAGNOSIS
The diagnosis menu allows access and testing of digital inputs, relay analog outputs, analog inputs of current transformers, phase control inputs (frequency, angle
and sequence) and membrane film buttons.
Name
Code
P20.01
P20.02
P20.03
P20.04
P20.05
P20.06
P20.07
P20.08
P20.09
P20.10
P20.11
P20.12
P20.13
P20.14
P20.15
P20.16
P20.17
P20.18*
Diagnosis
P20.19*
P20.20*
P20.21*
P20.22*
P20.23*
P20.24*
P20.25*
P20.26*
P20.27
P20.28
P20.29
P20.30
P20.31
P20.32
P20.33
P20.34
P20.35
P20.36
P20.37*
P20.38*
Press ENTER to access the sub-menus - *Editable only when the machine is stopped.
Reading and editing with keyboard or ECO card
MTR fan curr
Fan motor current. Press 'ENTER' to access the sub-menu.
Transformation ratio of the fan motor current sensor. Press 'ENTER'. Use the 'UP and DOWN' buttons to set between the
MTR fan curr
allowed values. Press 'ENTER'. The set value will be saved and the screen will return to the previous menu.
Winding the current transformer.
Press 'ENTER'. Use the 'UP and DOWN' buttons to set between the allowed values. Press 'ENTER'. The set value will be
TC Winding
saved and the screen will return to the previous menu.
Note: The value set in this parameter must correspond to the number of turns given with the main motor
power cable inside the current transformer.
Use to calibrate the sensor's maximum measurement range. Press 'ENTER'. Use the 'UP and DOWN' buttons to set betwe-
Measurement range
en the allowed values. Press 'ENTER'. The set value will be saved and the screen will return to the previous menu.
MTR fan curr
Non-editable. This parameter displays the value of the fan motor current being measured by the sensor.
Analog Input 5
Dew point temperature of the air dryer integrated into the compressor. Press 'ENTER' to access the sub-menu.
Use to calibrate the sensor offset. Press 'ENTER'. Use the 'UP and DOWN' buttons to set between the allowed values.
Offset measurement
Press 'ENTER'. The set value will be saved and the screen will return to the previous menu.
Analog Input 5
Non-editable. Dew point temperature value of the air dryer integrated into the compressor.
Table 8.10 - Diagnosis
Text
Additional information
Digit Input 1
Digit Input 2
Diagnosis of digital inputs. Information on the display toggles between the digital input number and the current input
Digit Input 3
value. Press 'ENTER' to check what the input refers to and its status.
Digit Input 4
Possible conditions for digital inputs:
Digit Input 5
Inactive = OK
Digit Input 6
Active = Not OK
Digit Input 7
Digit Input 8
Analog input 1 (mA)
Analog Input 2 (mA)
Diagnosis of analog inputs. Information on the display will switch between the analog input number and the measured
Analog Input 3 (resistive)
value (mA, resistive, current or voltage) for the analog input. Press 'ENTER' to check which magnitude is being measured
and its current value (E.g. Output pressure, 7.3 bar).
Analog Input 3 (current)
Analog Input 3 (voltage)
Control NET supply voltage (X13). Information on the display will switch between the analog input number and the
Entr analóg 4 (voltage)
measured voltage value.
Note: Analog input 4 has no other function other than to display the value of the interface supply voltage.
Analog Input 5 (resistive)
Note: Only visible when analog input 5 is detected.
Diagnosis of analog inputs. Information on the display will switch between the analog input number and the measured
Analog Input 5 (current)
value. Press 'ENTER' to check which magnitude is being measured and its corresponding current value (Ex: dew point
Analog Input 5 (voltage)
temperature, 2.5°C).
Relay output 1
Relay output 2
Relay output 3
Relay output 4
Press 'ENTER' and use 'UP' and 'DOWN' to power and de-energize the relay
Relay output 5
Relay output 6
Relay output 7
Relay output 8
Analog output 1
Press 'ENTER' and use 'UP' and 'DOWN' to set the output mA value
Analog Input CT1A
Current value in phase A of the main motor
Analog Input CT1B
Current value in phase B of the main motor
Analog Input CT1C
Current value in phase C of the main motor
Analog Input CT2A
Fan motor current value
Frequency L1
Voltage frequency in phase L1
Frequency L2
Voltage frequency in phase L2
Frequency L3
Voltage frequency in phase L3
Angle phase L1
Voltage angle of phase L1
Angle phase L2
Voltage angle of phase L2
Angle phase L3
Voltage angle of phase L3
Key test
Press 'ENTER' and then the membrane buttons to verify their operation
Note: only enabled when the LED module is detected.
LED Test
Press 'ENTER' and select 'off' or 'on'. When 'on' the LEDs will be lit sequentially until 'off' is selected.