P18.20
P18.21*
P18.22*
SETUP I/O
P18.23*
P18.24*
Press ENTER to access the sub-menus - *Editable only when the machine is stopped.
Reading and editing with keyboard or ECO card
8.9 SENSOR SETTINGS
IMPORTANT
Name
Code
P19.06*
P19.06.05*
P19.06.06*
P19.06.07
P19.07*
P19.07.05*
CONFIG
Sensor
P19.07.07
P19.08*
P19.08.01*
P19.08.03
P19.04*
P19.04.01*
P19.04.02*
P19.04.03*
P19.04.04*
Press ENTER to access the sub-menus - *Editable only when the machine is stopped.
Reading and editing with keyboard or ECO card
ANA IN 1 FUNCT
Used to verify analog input function 1. Can't edit it.
Parameter used to enable or disable analog input 2, which is responsible for measuring the equipment internal pressure.
ANA IN 2 FUNCT
Press 'ENTER'. Use the 'UP and DOWN' buttons to set to Off, or internal pressure. Press 'ENTER'. The selected value
will be stored in memory and the screen will return to the previous menu.
Used to setup the function associated with analog input 3.
Press 'ENTER'. Use the 'UP and DOWN' buttons to set to Off, Output Temp., Temp. dew point Press 'ENTER'. The selec-
ANA IN 3 FUNCT
ted value will be stored in memory and the screen will return to the previous menu.
Note: When the functions Output Temp. or Temp. dew point are enabled, all the logics associated with them
are also enabled.
Selects the type of temperature sensor being used. Press 'ENTER'. Use the 'UP and DOWN' buttons to configure
ANA input 3 Type
between KTY, PT100 or PT1000. Press 'ENTER'. The selected value will be stored in memory and the screen will return
to the previous menu.
ANA IN 5 FUNCT
Idem P18.22
ANA input 5 Type
Idem P18.23
Incorrect sensor settings can influence product performance and safety functions.
Table 8.9 - Sensor Settings
Text
Additional information
Analog Input 1
Compressor output pressure. Press 'ENTER' to access the sub-menu.
Use to calibrate the sensor offset.
Press 'ENTER'. Use the 'UP and DOWN' buttons to set between the allowed values. Press 'ENTER'. The set value will be
Offset medição
saved and the screen will return to the previous menu.
Note: To calibrate the offset, expose the sensor to the atmosphere and adjust the offset value until the value
shown in P19.06.07 is 0.0 bar.
Use to calibrate the sensor's maximum measurement range.
Press 'ENTER'. Use the 'UP and DOWN' buttons to set between the allowed values. Press 'ENTER'. The set value will be
Measurement range
saved and the screen will return to the previous menu.
Note: to calibrate the maximum sensor range, apply a known pressure to the sensor and adjust the measu-
rement range until the value shown in P19.06.07 reaches the applied value. The measurement range can be
calibrated at a static pressure or by modifying the applied pressure.
Analog Input 1
Output pressure. Non-editable. Output pressure measured by the sensor.
Analog Input 2
Compressor internal pressure. Press 'ENTER' to access the sub-menu.
Use to calibrate the sensor offset.
Press 'ENTER'. Use the 'UP and DOWN' buttons to set between the allowed values. Press 'ENTER'. The set value will be
Offset measurement
saved and the screen will return to the previous menu.
Note: To calibrate the offset, expose the sensor to the atmosphere and adjust the offset value until the value
shown in P19.07.07 is 0.0 bar.
Analog Input 2
Compressor internal pressure. Non-editable. Output pressure measured by the sensor.
Analog Input 3
Output or discharge temperature in the compressor unit. Press 'ENTER' to access the sub-menu.
Use to calibrate the sensor offset. Press 'ENTER'. Use the 'UP and DOWN' buttons to set between the allowed values.
Offset measurement
Press 'ENTER'. The set value will be saved and the screen will return to the previous menu.
Analog Input 3
Non-editable. Output temperature value in the compressor unit measured by the sensor.
Main MTR curr
Main motor current. Press 'ENTER' to access the sub-menu.
Transformation ratio of the main motor current sensor.
Press 'ENTER'. Use the 'UP and DOWN' buttons to set between the allowed values. Press 'ENTER'. The set value will be
Main MTR CT Range
saved and the screen will return to the previous menu.
Note: The value set in this parameter must be the same as the current transformer used for main motor
current measurement.
Winding the current transformer.
Press 'ENTER'. Use the 'UP and DOWN' buttons to set between the allowed values. Press 'ENTER'. The set value will be
TC Winding
saved and the screen will return to the previous menu.
Note: The value set in this parameter must correspond to the number of turns given with the main motor
power cable inside the current transformer.
Use to calibrate the sensor's maximum measurement range. Press 'ENTER'. Use the 'UP and DOWN' buttons to set betwe-
Measurement range
en the allowed values. Press 'ENTER'. The set value will be saved and the screen will return to the previous menu.
Non-editable. This parameter displays the value of the main motor current being measured by the sensor.
Main MTR curr