8.6 MENU DETAILS
Name
Code
P00.01
P00.02
P00.03
P00.04
P00.05
P00.06
Home
P00.07
P00.08
P00.09
P00.11
P00.12
P00.13
P00.14
P00.15
P00.16
P00.17
P00.18
Hour meter management for maintenance schedules.
P01.01
P01.02
P01.03
P01.04
P01.05
P01.06
P01.07
Hour Meters
P01.08
P01.09
P01.10
P01.11
P01.12
P01.13
P01.14
P01.15
P01.16
The Usage menu provides information on the compressor's operating routine. This menu provides useful information to assess the operating efficiency
of the product or its reliability.
P02.01
P02.02
P02.03
P02.04
P02.05
P02.06
Usage
P02.07
P02.08
P02.09
P02.10
P02.10.01
P02.10.02
P02.10.03
P02.10.04
Press ENTER to access the sub-menus
Read-Only
Table 8.6.1 - Menu Details
Text
Home page is the default screen that appears after an idle period. This page provides equipment status and conditional information.
Active alarm
Control Mode
Configurable
Configurable
Configurable
Output temperature
Output pressure
Internal pressure
Differential pressure
Main MTR curr
MTR fan curr
Time
Date
DST
GCI Sequence
Seq. Cycle - hours
XPM GCI Pressure
Total hours
HRS load/relief
Hours under load
Hours in relief
Hours stopped
Air filter maint. (configurable)
Oil filter maint. (configurable)
Separator maint. (configurable)
MTR grease maint. (configu-
rable)
Check oil (configurable)
Maint. hours (Configurable)
Maint. hours (Configurable)
Maint. hours (Configurable)
Weekly maintenance
Annual maintenance
Biannual maintenance
Equip Status
HRS load/relief
Part MTR last HR
Part MTR last 24h
Load freq.
Load % last hour
Load % last 24h
Load time last HR
Load time last 24h
Average VSD RPM
Average VSD RPM%
Average VSD RPM%
Average VSD RPM%
Average VSD RPM%
Additional information
Any active alarm will be displayed. If more than one alarm is active, they will be shown in chronological order.
Only the active alarm with higher priority will be visible. Active alarms are displayed until the corrective action
removes the alarm condition.
To view all active alarms, press
Use the keys
Press
or
to return to parameter P00.01
Control mode selected
Item P00.03 on the menu to be shown on the display, set by user
Item P00.04 on the menu to be shown on the display, set by user
Item P00.05 on the menu to be shown on the display, set by user
Output temperature in the compressor unit
Output pressure (pressure vessel)
Internal pressure (air-oil tank)
Differential pressure value (internal pressure minus outlet pressure).
Note: replaced by differential pressure switch, depending on the equipment version.
Main motor current reading (optional, requires TC)
Fan current reading (optional, requires TC)
Current time reading (as settings)
Current date reading (as settings)
DST indicator enabled
Indicator if the GCI manager control is on or off. When on, shows the active sequence.
Decreases the value in Hours when the next GCI sequential event will occur.
GCI XPM pressure sensor value (external module, optional, for remote network pressure reading).
Hour meter. Indicates the number of hours from the commissioning date (start-up).
Hour meter. Indicates the number of hours in load/relief.
Hour meter. Indicates the number of hours under load.
Hour meter. Indicates the number of hours in relief.
Hour meter. Indicates the number of hours energized and stopped.
Hour meter. Indicates the number of hours remaining for next maintenance on air filter. Configurable parame-
ter.
Hour meter. Indicates the number of hours remaining for next oil filter maintenance. Configurable parameter.
Hour meter. Indicates the number of hours remaining for next maintenance on air-oil separator. Configurable
parameter.
Hour meter. Indicates the number of hours remaining for next maintenance on electric motor. Configurable
parameter.
Hour meter. Indicates the number of hours remaining for next oil change. Configurable parameter.
Hour meter. Configurable parameter.
Hour meter. Configurable parameter.
Hour meter. Configurable parameter.
Time meter. Weekly Maintenance. Configurable parameter.
Time meter. Annual Maintenance. Configurable parameter.
Time meter. Bi-annual maintenance. Configurable parameter.
Equipment status, indicated as a numerical value (machine status diagram).
Hour meter. Indicates the number of hours in load/relief.
Start meter. Indicates the number of motor starts during the last hour.
Start meter. Indicates the number of motor starts during the last 24 hours.
Load-relief meter. Indicates the number of times the compressor has changed from the relief to load status.
Load percentage index during the last hour (load / load + relief)*100%.
Load percentage index during the last 24 hours (load / load + relief)*100%.
Load time during the last hour.
Load time during the last 24 hours (HH:MM).
Average RPM speed 1-100%.
Average RPM speed 1-25%.
Average RPM speed 26-50%.
Average RPM speed 51-75%.
Average RPM speed 76-100%.
206
e
to navigate and view all active alarms.