3.1 Down or decrease value
Each led has a specific function, as shown in the table below:
LED
7.0
102
BAR
85.6
186
ºC
23456
16420
420
Hr
1
Add
If one of the timers is activated (relief time, stop, standby or auto restart in case of power shortage), user menu will show the
t
remaining time, always in seconds. While the time is displayed, the normal user menu values may be seen pressing the DOWN key.
The display will show again the current temperature in case no key is pressed for a short period or if no timer is on.
3.2 Operation Display
The compressor operation mode is continuously shown using the operation symbols:
Standby: The compressor is in standby. The motor is not running, but the compressor may start automatically at any moment when
pressure decreases to a value lower than minimum pressure (PL) or when it receives a remote load command.
Running: The compressor is running offload (run-on-time active).
Loaded: The compressor is working onload
3.3 Fault Conditionsh
If a fault condition happens, a triangle will be shown on screen. If the fault is an alarm condition, the triangle will be shown
uninterruptedly. If it is an error leading to compressor shutting down, the triangle will blink. The user menu will display a fault code,
indicating which fault happened.
3.4 Maintenance hour meters
If one of the maintenance hour meters (H1, H2, H3,H4 and H5) reaches 0 (zero), a maintenance symbol will blink and a maintenance
code will be shown on user menu. The maintenance code may be reset but the maintenance symbol will still be displayed until the hour
meter is reset. The maintenance hours will continue to decrease in negative hours. The maintenance hour meters may be reset, using the
"operation menu", after the maintenance has been performed.
The maintenance hour meters may be set to any value, depending on the needed maintenance interval. The maintenance hour meters are
based on the compressor working hours.
H1: Hours for air filter exchange
H2: Hours for oil filter exchange
H3: Hours for separation element verification
H4: Hours for oil exchange
H5: Hours to grease for engine
Main Value: compressor output pressure (configurable: bar/psi)
PSI
Standard Value in User Menu: temperature (configurable: °C/°F)
ºF
Hr
LHr
Hours until maintenance H1 to H4 (countdown based on working hours)
RS 485 communication network address (*will be shown only if RS 485 module is
MEANING
To see other values in user menu, press UP or DOWN
Working hours
Load hours
installed)
23

Publicidad

loading