Item Nº
Description
12
Relay Output 4
13
Relay Output 5
14
Relay Output 6
15
Analog Input 1
16
Analog Input 2
17
Analog Input 3
18
Analog Output 1
Digital Inputs: The display will indicate the actual status of the inputs "_/_" (open circuit) or "_ _ _" (shorted circuit) and the status of the
corresponding input function: active (1) or inactive (0).
Note: The numerical value on the screen indicates the function, and not the input status (example: Emergency Stop = 0 "_ _ _" the input
is in shorted circuit, and the emergency Stop function is not active).
Outputs to relay: The relays can be powered (1) and unpowered (0). The outputs of the main motor relay, from 1 to 3, can only be powered
one at a time; the output will power itself off when the selected item is changed.
Analog inputs: The analog output values will alternate between the adjusted associated engineering units for real mV (tension and tempera-
ture inputs) or mA (current loop inputs), detected at the corresponding analog input connector. The value of the mV or mA can be checked
independently with a meter.
The output analog values can be adjusted (from 4,0 mA to 20,0 mA, in 0,1 mA steps) to force the output to a mA level desired for processes
of diagnosis or calibration. The output will automatically revert when exiting the menu.
4.4.9 - P07 Maintenance Menu
Item Nº
Description
1
Star/delta timeStep
2
Load delay
3
Reload delay
4
Load source
5
Start-up source
6
Address Rs485
7
Relay 5 function
8
Relay 6 function
9
Differential pressure delay
10
Information
11
Auto restart
12
Drain in release
13
Start-ups per hour
14
Analog input function
15
Fan Turn-on Temperature
16
Fan Turn-off Temperature
17
Fan Running
18
Units
mA
0= pressure sensor
1= remote communication
1= remote communication
2= digital inputs
1 a 13 see function
1 a 13 see function
0=no indication
1=network address
2= Status number
3= Average cycle time
4= maximum time cycle
5= # registered start-ups
Mode
Step
---
1
---
1
---
1
---
Reading
---
Reading
---
Reading
0,10
Units
Step
s
0,2
s
0,2
s
0,2
1
0= interface
1
---
1
1
1
s
1
1
s
1
s
1
---
1
---
1
°C / °F
1
°C / °F
1
s
1
---
1
93
Mín.
Máx.
0
1
0
1
0
1
---
---
---
---
---
---
4,0
20,0
Mín.
Máx.
1
30
1
30
1
10
0
1
0
2
1
99
1
13
1
13
1
600
0
5
0
120
0
30
0
20
0
17
60
100
59
99
0
120
0
1
Display
R4 0 - / -
R5 0 - / -
R6 0 - / -
A1 4,00mA
A2 0,467mA
A3 4,00mA
A4 4,00mA
Display
Y∆ 10,0sec
Lt 1,0sec
Rt 1,0sec
Ls 0
SS 0
Ad 1
R5 1
R6 1
∆P 10sec
ls 1
At 10sec
ud 0
Sh 0
Ao 15
Fh 85°C
FL 75°C
Ft 10sec

Publicidad