9.3 EVENT LIST
Each stored event (P04.01.01 - P04.01.200) includes an index, event description, and time and date that the event occurred. Examples:
• Pressed start button
• Pressed stop button
• Dryer On
• Admin user enabled
• Modified parameter
9.4 PARAMETERS FOR SETTING UP START AND/OR LOAD SOURCE
Parameters (notes):
• Discharge pressure sensor (standard)
• Digital input (requires setting an available digital input)
• Serial port with Airbus485™ protocol
• Serial port with MODBUS protocol
• Ethernet communication port TCP/IP (requires ethernet communication port, optional for some product models)
• Modified parameter
9.5 USING MENUS AND PARAMETERS
Users of the Control NET electronic interface should notice that the menus are arranged sequentially from P00 to P99. However, some menus are
intentionally omitted. This can happen for many reasons and is perfectly normal.
Numbers of the menus and their names are shown below:
Number
Menu name
P00
Start
P01
Hour Meters
P02
Usage
P03
Error list
P04
Event list
P05
Service provider
P06
Interface Data
P07
Compressor data
P08
Message codes
P09
Access
9.6 EQUIPMENT CONDITIONS OR STATUS CODES
Number
State
Stopped equipment
01
The stopped equipment status always occurs after an immediate stop condition. This status can only be removed from the interface when
the immediate stop condition that originated it is solved.
Powering up
02
Control NET Interface boot
Start impediment
03
A start impediment is usually associated with a start impediment condition, such as an impediment related to open cabinet door, low
temperature or elevated internal pressure.
04
Ready to start
Cooling
When set, a cooling status precedes the start of the compressor. Cooling time is a period used to ensure that the compressor internal
05
pressure has reached a value low enough to enable the compressor to start safely.
Note: Factory-set cooling time ensures that the compressor is started safely. This value should not be changed by the user.
Standby
Other conditions may prevent the compressor from starting. When this condition is active the interface announces that the equipment is
waiting for the condition that prevents the start of the compressor to be solved.
06
These conditions may occur during normal equipment operation. For example, if the start button is pressed at the time the compressor
discharge pressure is greater than the set load pressure, the compressor will remain in standby until the discharge pressure is lower than
the load pressure.
Table 9.5 - Menus and Parameters
Number
Menu name
P10
Equipment 1 settings
P11
Equipment 2 settings
P12
Equipment 3 settings
P13
FLEX Settings
P14
Motor protection
P15
Impediments
P16
Warning alarms
P17
Immediate stop alarms
P18
Input and output settings
P19
Sensor settings
Table 9.6 - Equipment Conditions or Status Codes
232
Number
Menu name
P20
Diagnosis
P21
Run scheduling
P30
Table of compressors
P40
User 1 settings
P60
LED Settings
P80
GCI main menu (manager)
P81
GCI Settings (Manager)
P82
GCI Priority (Manager)