P17.16
P17.17
P17.18
P17.19
P17.20
P17.21
P17.22
P17.23
Immediate stop
alarm (Errors)
P17.24
P17.24.01
P17.24.02
P17.25
P17.25.01
P17.25.02
P17.26
P17.26.01
P17.26.02
P17.32
Press ENTER to access the sub-menus - *Editable only when the machine is stopped.
Reading and editing with keyboard or ECO card
Belt (s) maintenance error
Belt maint.
Press 'ENTER'. Use the 'UP' and 'DOWN' buttons to set between Off or On. The selected value will be stored and the
screen will return to the previous menu.
Note: requires association with a digital input. Check P18 menu.
Dryer failure error.
Dryer alarm
Press 'ENTER'. Use the 'UP' and 'DOWN' buttons to set between Off or On. The selected value will be stored and the
screen will return to the previous menu.
Note: requires association with a digital input. Check P18 menu.
Water flow error.
Water flow
Press 'ENTER'. Use the 'UP' and 'DOWN' buttons to set between Off or On. The selected value will be stored and the
screen will return to the previous menu.
Note: requires association with a digital input. Check P18 menu.
Frequency inverter failure error.
Inverter failure
Use the 'UP' and 'DOWN' buttons to set between Off or On. The selected value will be stored and the screen will return to
the previous menu.
Note: requires association with a digital input. Check P18 menu.
Main motor high temperature error.
High temp main MTR
Press 'ENTER'. Use the 'UP' and 'DOWN' buttons to set between Off or On. The selected value will be stored and the
screen will return to the previous menu.
Note: requires association with a digital input. Check P18 menu.
High output temperature error.
High output temp
Press 'ENTER'. Use the 'UP' and 'DOWN' buttons to set between Off or On. The selected value will be stored and the
screen will return to the previous menu.
Note: requires association with a digital input. Check P18 menu.
Cooling system failure error.
Cool system failure
Press 'ENTER'. Use the 'UP' and 'DOWN' buttons to set between Off or On. The selected value will be stored and the
screen will return to the previous menu.
Note: requires association with a digital input. Check P18 menu.
Main motor failure error.
Main MTR failure
Press 'ENTER'. Use the 'UP' and 'DOWN' buttons to set between Off or On. The selected value will be stored and the
screen will return to the previous menu.
Note: requires association with a digital input. Check P18 menu.
CNF immed stop 1
Configurable error 1. Press 'ENTER' to access the sub-menu.
Enables configurable error 1.
ON CNF immed stop
Press 'ENTER'. Use the 'UP' and 'DOWN' buttons to set between Off or On. The selected value will be stored and the
screen will return to the previous menu.
Note: requires association with a digital input. Check P18 menu.
The immediate stop error name is a text that can be entered in the interface. This text can be used in menu P00.01 (main
menu) and menu P03 (error log). Press 'ENTER' to access the text editing menu. The current error text will be displayed and
Immed stop name
the first digit will be selected. Use the 'UP' and 'DOWN' buttons to set the name and press 'ENTER'. The value of the first
letter is saved and the second letter is selected. Complete the process with the other letters. When the operator presses
'ENTER' after the eighth letter, the word is stored and the screen returns to the previous menu.
Cnf immed stop 2
Configurable error 2. Press 'ENTER' to access the sub-menu.
Enables configurable error 2.
ON CNF immed stop
Press 'ENTER'. Use the 'UP' and 'DOWN' buttons to set between Off or On. The selected value will be stored and the
screen will return to the previous menu.
Note: requires association with a digital input. Check P18 menu.
The immediate stop error name is a text that can be entered in the interface. This text can be used in menu P00.01 (main
menu) and menu P03 (error log). Press 'ENTER' to access the text editing menu. The current error text will be displayed and
Immed stop name
the first digit will be selected. Use the 'UP' and 'DOWN' buttons to set the name and press 'ENTER'. The value of the first
letter is saved and the second letter is selected. Complete the process with the other letters. When the operator presses
'ENTER' after the eighth letter, the word is stored and the screen returns to the previous menu.
Cnf immed stop 3
Configurable error 3. Press 'ENTER' to access the sub-menu.
Enables configurable error 3.
ON CNF immed stop
Press 'ENTER'. Use the 'UP' and 'DOWN' buttons to set between Off or On. The selected value will be stored and the
screen will return to the previous menu.
Note: requires association with a digital input. Check P18 menu.
The immediate stop error name is a text that can be entered in the interface. This text can be used in menu P00.01 (main
menu) and menu P03 (error log). Press 'ENTER' to access the text editing menu. The current error text will be displayed and
Immed stop name
the first digit will be selected. Use the 'UP' and 'DOWN' buttons to set the name and press 'ENTER'. The value of the first
letter is saved and the second letter is selected. Complete the process with the other letters. When the operator presses
'ENTER' after the eighth letter, the word is stored and the screen returns to the previous menu.
Failure error on fan motor inverter.
Ovl mot inv fan
Press 'ENTER'. Use the 'UP' and 'DOWN' buttons to set between Off or On. The selected value will be stored and the
screen will return to the previous menu.
Note: requires association with a digital input. Check P18 menu.
223