E:0085
Fan MTR curr. sen.
E:0086
Fan Motor Overload
E:0090
Phase Sequence
E:0091
L1 phase failure
E:0092
L2 phase failure
E:0093
L3 phase failure
E:0115
Pressure sens. failure
E:0119
High discharge pres.
E:0125
Failure temp. sens.
E:0129
High output temp
E:0131
Low internal pres.
E:0135
Int. pres. sens. failure
E:0139
High int. pres.
E:0184
Cooling failure
E:0200
Cooling water failure
E:0229
Fast temp. increase
E:0809
High dif pres.
E:0814
Cooling failure
E:0821
Short circuit
E:0846
Discharge pres. sens. range Immediate Stop: Discharge pressure sensor range
E:0856
Int. pres. sens. range
E:0901
Failure user 1
E:0902
Failure user 2
E:0903
Failure user 3
E:2032
Line filter DP
E:2915
GCI pres. sens.
E:2950
GCI pres. sens. range
E:2960
GCI Communication
E:2980
GCI Dig. Input
E:3230
Open doors
E:5002
Technical assist.
R:3123
Low temp.
R:3137
High int. Pres.
S:3500
Start imp.
S:3501
Start imp.
9.2 LANGUAGE CODES
Immediate stop: Fan motor current sensor failure
Immediate Stop: Fan Motor Overload
Immediate Stop: Main motor phase sequence
Immediate stop: Phase failure on main motor (L1)
Immediate stop: Phase failure on main motor (L2)
Immediate stop: Phase failure on main motor (L3)
Immediate stop: Discharge pressure sensor failure
Immediate Stop: High discharge pressure
Immediate stop: Temperature sensor failure
Immediate stop: High temperature
Immediate Stop: Low internal pressure
Immediate stop: Internal pressure sensor failure
Immediate Stop: High internal pressure
Immediate stop: Cooling failure
Immediate Stop: Compressor cooling water failure
Immediate Stop: Very high discharge temperature increase rate
Immediate stop: High differential pressure
Immediate stop: Cooling failure
Immediate stop: Short circuit
Immediate Stop: Internal pressure sensor range
Immediate Stop: Immediate stop 1 set by user
Immediate Stop: Immediate stop 2 set by user
Immediate Stop: Immediate stop 3 set by user
Immediate Stop: Line filter differential pressure
Immediate Stop: GCI pressure sensor
Immediate Stop: GCI pressure sensor range
Immediate Stop: Communication failure with GCI module
Immediate Stop: GCI digital input
Immediate Stop: Cabinet doors open
Immediate Stop: Contact Schulz Technical Assistance
Operating impediment: Low discharge temperature
Operating impediment: High internal pressure
Start impediment: Operator
Start impediment: Open door
Table 9.2 - Language Codes
Code
Language
EN
English
BEL
Belarusian
BRA
Portuguese (BRA)
CZE
Czech
DE
German
ES
Spanish
FR
French
GRE
Greek
IT
Italian
JPN
Japanese
KOR
Korean
NL
Dutch
PER
Persian
PL
Polish
PT
Portuguese Portugal)
RU
Russian
TH
Thai
TR
Turkish
UKR
Ukrainian
VI
Vietnamese
ZH (S)
Simplified Chinese
ZH (T)
Traditional Chinese
231