NAVIGATION THROUGH THE MENUS
4. Navigation through the menus
Parameters, values and options may be adjusted in "operation" and "configuration" menus.
1) Operation menu: access code: "0009".
2) Configuration menu: access code: "0121".
To access the menus, first turn the compressor off, and then press the UP and DOWN keys at the same time. The display will
show four zeros; the first zero will blink. Press UP or DOWN to adjust the first digit of the required access code. Press ENTER to
change the second digit.
When the four digits are adjusted, and the last one is blinking, press ENTER. If the access code is correct for one of
both menus, the first item of the menu will be displayed. If the access code is wrong, the display will return to the
standard operational screen.
To select a menu item to be adjusted, press UP or DOWN until the item is on the display. To adjust the item, press ENTER; the item value
will blink. Press UP or DOWN to adjust the value as desired. Press ENTER to store the information in memory.
To exit the menu and return to the standard operational menu, at any time, press RESET. Any configuration not stored in memory
will be lost and the old value will be kept.
4.1 Operation menu
ITEM
1
1.H1
Hours for air filter exchange
2
1.H2
Hours for oil filter exchange
3
1.H3
Hours for separation element verification
4
1.H4
Hours for oil exchange
5
1.H5
Hours to grease for engine
6
1.Pu
Unload pressure
7
1.PL
Load pressure
8
1.rt
Run-on-time
9
1.bt
Blowdown time
10
1.St
Stop time
11
1.P-
Pressure unit
12
1.t-
Temperature unit
13
1.At
Auto restart time
(*) These values may vary according to the compressor model.
Pressure control:
The compressor will keep pressure between the Pu (Relief Pressure) and PL (Load Pressure) values. When pressure reaches Pu value, the
compressor will enter relief mode. When pressure falls to PL value, compressor will enter load mode.
Run-on-time:
When the compressor is in relief, the relief timer will be activated. If the compressor is in relief during the relief time, the main motor will
stop and the compressor will enter standby. When pressure reaches the PL value, the main motor will start automatically.
Blowdown time:
When the main motor stops, it will only start again after the standby time. Motor startup is not allowed during this period. This time is
necessary in order for the compressor's internal pressure to decrease, making the next compressor startup easier.
DESCRIPTION
24
RANGE
-999 to 9999 hours
1000 hours
-999 to 9999 hours
1000 hours
-999 to 9999 hours
3000 hours
-999 to 9999 hours
1000 hours
-999 to 9999 hours
2000 hours
1 to 68bar
7.0bar
0.8 to 67.8bar
6.8bar
0 to 600 seconds
300 seconds (5 Min.)
0 to 120 seconds
30 seconds
0 to 30 seconds
10 seconds
bar/psi
bar
°C/°F
°C
0 to 120 seconds
10 seconds
STANDARD(*)