P10.09.07
P10.10
P10.10.01
P10.10.02
P10.10.03
P10 – Config. EQUIP 1
P10.10.04
P10.10.05
P10.10.06
P10.10.07
P10.12*
P10.13*
P10 – Config. EQUIP 1
P10.14
P10.15
P10.16
P10.17
P10.18
P10.18.01
P10.18.02
P10.18.03
P10.18.04
P10.19
Press ENTER to access the sub-menus - *Editable only when the machine is stopped
Reading and editing with keyboard or ECO card
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set between 1 and 3. Press 'ENTER'. The set value is stored in
MODBUS end bits
memory and the browser returns to P10.09.07.
RS485: SETUP 2
Press 'ENTER' to access RS485: sub-menu setting 2.
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to select between 'Airbus485TM', 'MODBUS master' or 'MODBUS
RS485: SETUP 2
slave'. Press 'ENTER'. The set value is stored in memory and the browser returns to P10.10.01.
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to select between 1 and 200 (unit pitch). Press 'ENTER'. The set value
Endereço Airbus485™
is stored in memory and the browser returns to P10.10.02.
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to select between 1 and 200 (unit pitch). Press 'ENTER'. The set value
Endereço MODBUS
is stored in memory and the browser returns to P10.10.03.
Press 'ENTER'. Use the UP and DOWN arrows to select between 300, 600, 1200, 1800, 2400, 4800, 9600, 14400, 19200,
Taxa Transm MODBUS
28800, 38400, 57600, 115200, 230400, 460800 and 931600. Press 'ENTER'. The set value
is stored in memory and the browser returns to P10.10.04
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to select between 'no parity', 'even parity', 'odd parity', 'zero parity' or
Paridade MODBUS
'parity one'. Press 'ENTER'. The set value is stored in memory and the browser returns to P10.10.05.
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set between 5 and 8. Press 'ENTER'. The set value is stored in
Bits dados MODBUS
memory and the browser returns to P10.10.06.
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set between 1 and 3. Press 'ENTER'. The set value is stored in
Bits fim MODBUS
memory and the browser returns to P10.10.07.
The starting source is commonly associated with the 'START' button. In addition to this, you can configure other starting
sources. See the notes below!
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set 'INTERFACE BUTTON', 'EQUIPMENT DI' or 'COMMUNICATIONS'.
Press 'ENTER'. The set value is stored in memory and the browser returns to P10.12.
Notas:
- Only the selected starting source method is activated (only one). When selected, all other alternative starting source
methods will be inactivated!
- Any start command simply requests the compressor to go to the initial starting status. In this condition, the compressor
Starting source
may not necessarily go to another status (e.g. in operation, under load). Settings of the restrictive functions, timers and
load source will still continue to influence the operating features after the start command.
- When set to 'INTERFACE BUTTON', the 'START' button will be the starting source and the 'STOP' button will be the
stop source.
- When set to 'EQUIPMENT DI', the 'normal' status of the digital input (that is, normally open or normally closed) will be
the starting source and the alternative (reverse) status of that input will be the stop source.
- The 'normal' status of the digital inputs can be configured for either 'normally open' or 'normally closed'. Pay close
attention to this setting for correct operation of the machine.
- When set to 'EQUIPMENT DI', an available digital input must be properly set to 'COMP START / STOP'.
- When set to 'COMMUNICATIONS' an appropriate RS485 port needs to be installed and configured for that use.
Load source setup. Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set 'OUTPUT PRESSURE', 'EQUIPMENT DI' or
'COMMUNICATIONS'. Press 'ENTER'. The set value is stored in memory and the browser returns to P10.13.
Notes: When set to 'EQUIPMENT DI', two available digital inputs need to be properly set to 'ENABLE REMO-
Load source
TE LOAD' and 'REMOTE LOAD/RELIEF'.
When set to 'COMMUNICATIONS' an appropriate RS485 port needs to be installed and configured for that
use.
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to select the language. Press 'ENTER'. The selected value is stored in
Language
memory and the browser returns to P10.14.
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to adjust the time. Press 'ENTER'. The selected value is stored in
Time
memory and the browser returns to P10.15.
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to select the time format (12 hours AM/PM or 24 hours). Press 'ENTER'.
Time format
The selected value is stored in memory and the browser returns to P10.16.
Press 'ENTER'. Set between '+ 0h' or '+ 1h'. Press 'ENTER' again. The selected value is stored in memory and the
DST
browser returns to P10.17.
Date
Press 'ENTER' to access the date edit sub-menu.
Year
Use the 'UP' and 'DOWN' arrows to set the year.
Month
Use the 'UP' and 'DOWN' arrows to set the month.
Day
Use the 'UP' and 'DOWN' arrows to set the day.
Press 'ENTER' to save the set P10.18.01-P10.18.03 values and return to P10.18.
Save changes
Note: You need to save the new P10.18.01-P10.18.03 set values using P10.18.04 before leaving the sub-menu!
Press 'ENTER'. Use the 'UP' and 'DOWN' arrows to set the date format (DD/MM/YYYY or MM/DD/YYYY or YYYY/MM/
DD). Press 'ENTER' again. The set value is stored in memory and the browser returns to P10.19.
Date format
Note:
DD: day with 2 digits (01 to 31)
MM: month with 2 digits (01 to 12) YYYY: year with 4 digits (e.g. 2015)