4.3 - DISPLAY
The normal operation display offers continuous information about 4 value classes:
Line Pressure:
Status:
Enabled Functions:
Item Selected by the user:
Status
The Status is represented by symbols and is continuously displayed:
Pressure Control
The pressure is below load pressure (P1)
The pressure is between load (P1) and unload (P4) pressure
The pressure is above unload pressure (P4)
Compressor Off
Standby Mode
Operating in unload
Operating in load
Functions
The activated functions are represented by symbols and are displayed continuously.
The condensate drain outlet is powered on.
Line pressure adjusting RS485 (flashing = communication fault)
Automatic Restart due to power loss
Enabled Remote Load/Unload (digital input)
Remote Start-up/Stop control
Pressure Scheduling (flashing = overlapped pressure scheduling)
Item Selected by User
The user can navigate on the list of status items, information and values, using the buttons UP or DOWN.
Fault Indications
If a fault condition is active, the code and the fault identification will appear on the display. An active fault code becomes an additional item
in the user menu. If more than one fault condition is active; each one will become a separate item in the user menu. The user menu item will
disappear when a fault condition is solved and reset.
The fault types are identified by symbols; the symbol of the fault type will alternate with the fault code identification symbol(s).
Shutdown, General Failure, Immediate Stop
Alarm, Warning
Start-up, Load or Operation Impediment
Each fault code is unique and is presented with the identification symbol(s) and a description text (see "Fault Codes").
1
4
5
8
7: Symbol; identification
1: Value
3: Symbol
4: Symbol
5: Value
86
2
3
7
6
2: Unit
6: Unit
8: Text; Language