P18.02 ~ 14*
(Continuation)
SETUP I/O
P18.03 ~ 15*
Control NET interface has 8 relay outputs in which 4 of them are configurable.
The settings options are as follows:
Name
Code
SETUP I/O
P18.16 ~ P18.19*
Press ENTER to access the sub-menus - *Editable only when the machine is stopped.
Reading and editing with keyboard or ECO card
Exe SCH On/Off
Setting to enable or disable remote scheduling
DI Remote Start
Setting to enable remote start
Enable Load R
Setting to enable the remote load function
REM Load/Relief
Setting to enable remote load/relief function
Main MTR overload
Error indicating overload on main motor
Alarm 1 SETUP
Setup 1 for user-defined alarm
Alarm 2 SETUP
Setup 2 for user-defined alarm
Alarm 3 SETUP
Setup 3 for user-defined alarm
User Error 1
Setup 1 for user-defined error
User Error 2
Setup 2 for user-defined error
User Error 3
Setup 3 for user-defined error
Water flow
Error indicating water flow failure
Inverter failure
Error indicating frequency inverter failure
High room temp
Alarm indicating high room temperature
High temp main MTR
Error indicating main motor high temperature
High output temp
Error indicating high output temperature
Main MTR failure
Error indicating main motor failure
Cool system failure
Error indicating cooling system failure
Alarm FDB func
Alarm indicating issues in the feedback function
Check immed stop
Error on immediate stop verification
Reset Active Fault
Alarm on active fault verification
Ovl mot inv fan
Fan motor inverter overload alarm
Ovl mot inv fan
Fan motor inverter overload error
Ovl mot vent
Fan motor overload alarm
Ovl mot vent
Fan motor overload error
High oil temp
High oil temperature alarm
High oil temp
High oil temperature error
Input setting as normally open (Open) or normally closed (Closed).
Closed / Open
Note: Normally means correct status, without failures.
Table 8.8.3 - Input and Output Settings
Text
Additional information
Off
Relay output disabled
Alarm
Powered in any alarm condition (not including start impediment conditions)
Immediate stop
Powered for any active error (not including start impediment conditions)
Group error
Powered for any alarm, start impediment error
Alarm & Maintenance
Powered for any fault or maintenance alarm (not including start impediment conditions)
Maintenance
Powered for any active maintenance alarm.
Powered if the compressor unit discharge temperature reaches a value less than the start impediment temperature (for
Heater
example +2ºC). De-energizes if the temperature is above the start impediment temperature. Can be used to power an
anti-condensation heater or as a low temperature auxiliary alarm.
Purge NO
See parameters P11.09 and P11.10
Powered in all conditions in which the main motor is running after starting. It can be used to power the contactor of a
Fan
fan or internal or external ventilation system.
Standby
Powered in all conditions in which the product is on a standby or cooling mode.
In operation
Powered at all times when the main motor is running.
On Load
Powered at all times when the compressor is on load
Started
Powered in all situations where the compressor has started.
Enabled to operate under all conditions where the main motor is running except during its start. If enabled, to power the
Contr
Fan
output, it will only power up if the load temperature exceeds the value of the Temp fan on (P12.17). If the temperature
drops below the Temp fan off (P12.18) the output will be de-energized.
Dryer Control
Powered at all times when the main motor is running.
CR Start/Stop
Powered when remote start / stop is enabled.
CR load/relief
Energized when remote load/relief input is enabled.
Alarm NA
De-energized in any fault alarm condition (not including start impediment conditions)
IMMED Stop NA
De-energized for any active error (not including start impediment conditions)
Group failure NA
De-energized for any alarm, start impediment or active fault.
Alarm maint. NA
De-energized for any fault or maintenance alarm (not including start impediment conditions)
Powered when digital input of "inverter failure" is not OK
RST inv failure
Note: The relay output must be used in conjunction with an inverter digital input to reset the inverter.
Impediments
Powered whenever a start impediment condition is active
Purge NC
See parameters P11.09 and P11.10
225