5.10 Diagnosis
Item
Description
With "Scheme" function, the current context for the desired visualization can be selected. Depending on the
Scheme
selection of plan from the selection list, the context of the displayed curves changes. These are given a color
assignment specified in the legend. See schemes
Depending on whether the scheme displays time-dependent or position-dependent values, the expiring control
time or the measuring length configured in the encoder are displayed on X axis. The Y values are based on the
selected scheme.
The scheme cannot be changed during a running measurement.
Device
Selecting the target Servo Driver.
Axis
When several identical functions are used, they can be selected and displayed separately via this selection.
The values of these measured data are displayed for the respective relevant cursor positions.
Capture / Stop
Start or stop the recording.
Press the "Hold" button to pause the displayed values in the main diagram. Press "Continue" button to resume.
Hold / Continue
The data is still available in the cache.
Reset
Reset the graph values and process data.
The pointer is inserted at this point by double-clicking on the main diagram window. This adds the cursor to the
optional measurement table.
Save
If the area has been stopped, the current recording can be saved in a file. The range data is written to the file as
ASCII values. The individual values have XML markers, so the recording can be used for documentation
purposes or for the analysis associated with the encoder configuration. The data can also be viewed with the
current Microsoft Explorer or with another XML viewer.
This control area can be used to load a measurement stored in the area function in an XML file. In this case, the
Load
area window changes to the view mode. Due to possible differences in the encoder configuration of the
displayed measurement to the current program and the resulting deviations in the scaling of the position and
speed values, "Start" button and the plan selection list are deactivated after the data has been loaded to the
display. The measurements remain disabled until the range function is restarted.
Hold on change
If "Hold on change" checkbox is checked,the displayed values in the main diagram is paused, after an edge
change of the corresponding output (see above). This function allows long-term recording and error analysis in
the absence of the operator. Press "Continue" button to resume.
Scaling
By scaling the graph function, you can adjust Y values in the individual curves via the slider bar 1/2.
5.10.3 Flow during measurement in the range
After the range window has been opened, it is still set to "Stop", i.e. no cyclic process data is read from AC
Servo Driver MINAS A6 Multi series.
Perform measurement according to the following procedure.
5-25
Scrollbar 1
Changes the visible range of Y values in the diagram.
Changes the displayed maximum range of Y values in the
Scrollbar 2
diagram.