Drying Cycle
The "drying" function will run a cycle of forced
ventilation.
The opening of the door will not affect the running
cycle.
GB
To run the cycle press in correspondence of the
area
.
During a current cycle, following screenshot will be
displayed :
Defrosting Cycle
The frost formed on the evaporator following
the moisture deposit ceded by the product may
compromise the proper operation of the equipment.
To restore the full functionality it is necessary to
perform a defrosting cycle.
The defrosting is performed by forced ventilation
using the evaporator fan. The cycle can be
performed with the door open or closed and can
also be interrupted at any time.
By selecting the manual defrosting cycle the
system shows following screen:
Pressing on the area
temperatures detected by the various probes, the
state of inputs / outputs and the alarms stored by
the system. To abort the current cycle press for at
least three seconds the area
To run the cycle press in correspondence of the
area
.
During a current cycle, following screenshot will be
displayed :
Pressing on the area
temperatures detected by the various probes, the
state of inputs / outputs and the alarms stored by
the system. To abort the current cycle press for at
least three seconds the area