Rated motor temperature rise
Mot T_ambient
p0625[M]
Mot T_over core
p0626[M]
[8016.2]
Mot T_over stator
p0627[M]
Mot T_over rotor
p0628[M]
<1> Only if p0610.12 = 1.
1
2
DO: SERVO, VECTOR
Signals and monitoring functions - Thermal motor model 2
Stat therm iron
Stat therm weight
p0617[M]
p0619[M]
Thermal motor model 2
Only for:
induction motors
<1>
Mot temp resp
Stat therm copper
Mot weight th mod
p0610[M] (12)
p0618[M]
p0344[M]
3
4
Activate thermal motor model 2
p0612.1[M] (1)
Calculated motor temperatures
Mot T_environ
r0630[M]
Mot T_stator
r0631[M]
Mot T_copper
r0632[M]
Mot T_rotor
r0633[M]
Power losses calculated
r5395[M]
5
6
fp_8018_54_eng.vsd
31.03.20 V05.02.03
192.00 ms