24 V DC to the next device
X524.+
+24 V
X524.+
X524.M
0 V
X524.M
X514.+
X514.+
X514.M
X514.M
X521.6
X521.5
X521.1
<1>
X521.2
<1>
<1> The connection shown
as a dashed line applies
X522.5
when used as digital
<1>
X522.6
output (p4028.x = 1).
In this case, the terminal
block must be supplied
(+24 V_1/M1).
1
2
DO: TM41
Terminal Module 41 (TM41) - Digital inputs/outputs, bidirectional (DI/DO 0 ... DI/DO 1)
+24 V
M
M
+24 V_1
+24 V_1
M
M
+24 V_1
+24 V_1
p4028.8 (0)
DI
DI
0
24 V
DI/DO 0
1
DO
DO
p4028.9 (0)
DI
DI
0
DI/DO 1
5 V
1
DO
DO
M1
M
3
4
p4096.8 (0)
p4095.8 (0)
r4021.8
1
0
p4048.8 (0)
0
1
1
1
r4047.8
p4096.9 (0)
p4095.9 (0)
0
r4021.9
1
0
p4048.9 (0)
0
1
1
1
r4047.9
0
0
5
6
fp_9661_51_eng.vsd
22.04.09 V05.02.03
p4099[0] (4000.00 µs)
DI/DO 0 ... 1
DI/DO 0 ... 1
inverted
r4023
r4022
1
r4023.8
r4022.8
TM41 S_src DI/DO 0
p4038
(0)
1
r4023.9
r4022.9
TM41 S_src DI/DO 1
p4039
(0)
DI/DO: Bidirectional Digital Input/Output
7
8
Function diagram
- 9661 -
SINAMICS

Publicidad

loading

Este manual también es adecuado para:

Sinamics s150