n_limit pos
n_limit pos
0.000...210 000.000 [rpm]
p1083[D]
p1083[D] (210 000.000)
n_limit neg
n_limit neg
-210 000.000...0.000 [rpm]
p1086[D]
p1086[D] (-210 000.000)
<1>
With OFF1/OFF3, the deceleration ramp of the basic ramp-function generator is active (p1135 or p1121).
<100> Applies only if the function module "extended setpoint channel" (r0108.8 = 0) is not active. For r0108.8 = 1, [3050] applies instead of [3095].
1
2
DO: SERVO
Setpoint channel not activated - Generation of the speed limits (r0108.8 = 0)
p1081
Maximum speed
0.000...210 000.000 [rpm]
p1082[D] (1500.000)
3
4
Min
-1
Max
5
6
fp_3095_01_eng.vsd
01.08.13 V05.02.03
p0115[3] (4000.00 µs)
<1>
<100>
n_limit pos eff
r1084
[3020.6]
Speed limits if a setpoint channel
[3060.4]
has not been activated
[3070.4]
(r0108.8 = 0).
[5300.1]
n_limit neg eff
r1087
7
8
Function diagram