<2>
<3>
p0840[C] (0)
OFF2 S_src 1 (electrical)
<3>
p0844[C]
(1)
&
p0845[C]
(1)
OFF2 S_src 2 (electrical)
p0852[C] (1)
<3>
p3533[C] (0)
p0854[C] (0)
<3>
<1> STW1.10 must be set to ensure that the drive object accepts
the process data (PZD).
<2> PROFIdrive interconnection: For the manufacturer-specific
PROFIdrive telegram, the upper input is connected to
PROFIdrive signal E_STW1 [2447]. This only involves CDS0.
<3> Is pre-defined via the PC if the master control is retrieved.
1
2
DO: S_INF
Smart Infeed - Control word, sequence control infeed
Bit No.
Control word sequence control infeed
= ON (close precharging/line contactor, pulses can be enabled)
0
0 = OFF1 (pulse suppression and open precharging/line contactor)
1 = OC (enable is possible)
1
0 = OFF2 (immediate pulse suppression and power on inhibit)
2
Reserved
1 = Operation enable (pulses can be enabled)
3
0 = Inhibit operation (suppress pulses)
4
Reserved
5
Reserved
6
1 = Inhibit regenerative operation
7
Reserved
8
Reserved
9
Reserved
10
1 = Control by PLC
<1>
11
Reserved
12
Reserved
13
Reserved
14
Reserved
15
Reserved
3
4
5
6
Function diagram
fp_8820_01_eng.vsd
SINAMICS S120
09.11.18 V05.02.03
p0115[3]
STW seq_ctrl INF
r0898
r0898.0
To the sequencer [8832]
r0898.1
To the sequencer [8832]
r0898.3
To the sequencer [8832]
r0898.6
r0898.10
7
8
- 8820 -