n_ctrl config
p1400[D]
<1> Only for VECTOR.
1
2
DO: VECTOR, VECTOR3P, VECTORGL, VECTORM2C, VECTORSL
Vector control - Speed control configuration
Speed control configuration
Bit No.
Meaning
0
1 = Automatic Kp/Tn adaptation active
1
1 = Sensorless vector control, freeze I component
2
Acceleration pre-control, signal source: 1 = External (p1495) , 0 = Internal (n_set)
3
Reference model speed setpoint, I component: 1 = ON, 0 = OFF
4
Reserved
5
1 = Kp/Tn adaptation active
6
1 = Free Tn adaptation active
7
1 = Interpolation speed pre-control active
8
Reserved
9
Reserved
10
1 = Speed pre-control active
11
Reserved
12
Reserved
13
Reserved
14
Torque pre-control: 1 = Always active, 0 = For n_ctrl enabled
15
1 = Sensorless vector control, speed pre-control active
16
I component for limiting: 1 = Enable, 0 = Hold
17
Reserved
18
1 = Moment of inertia estimator active
19
1 = Anti-windup for integral component active
20
Acceleration model: 1 = ON, 0 = OFF
21
Reserved
22
1 = Obtain moment of inertia estimator value for pulse inhibit
23
1 = Acceleration model (with speed encoder)
24
1 = Moment of inertia estimator fast estimation active
25
1 = Acceleration torque instantaneous in the I/f mode
26
Reserved
27
Reserved
28
Reserved
29
Reserved
30
Reserved
31
Reserved
3
4
Factory setting
1
[6040.3]
0
[6040.5]
0
[6031.2] [6031.6]
0
[6031.1] [6031.6] [6031.7]
1
[6040.3]
0
[6050.6]
0
[6030.7] <1>
0
[6031.1] [6031.6]
0
[6060.4]
1
[6030.6] <1>
0
<1>
0
0
0
0
0
<1>
0
<1>
0
<1>
0
<1>
5
6
Function diagram
fp_6490_51_eng.vsd
SINAMICS
14.05.20 V05.02.03
p0115[1] (Motor Modules)