INSTAllATION
9) Calibrating the vacuum sensor.
Must be calibrated so as to adapt the reading to the elevation of the installation site.
Without this adjustment, the machine not creates an adequate vacuum.
Proceed as follows:
Turn the machine on using the "ON/OFF" main switch and
simultaneously press the "PROG" button.
Lower the lid.
The machine starts the cycle, which ends after approximately 2 minutes.
The lid opens at the end of the calibration.
The machine returns to the default program or the previously set program.
10) Choose the language of the display.
The machines are usually supplied with the language used in the country of destination of the appliance.
If you still want to choose a different language from those available (English, Italian, Spanish, French and German),
proceed as follows:
Turn the machine on using the ON/OFF main switch and
simultaneously press the "SEl" button.
Choose the language by pressing the "UP" and "DOWN"
buttons.
Confirm your selection with the "PROG" button, or wait 20 seconds after
which, the choice is saved.
36
Rev. 01 - 03/2018 - Cod. 1500024 - Instruction manual for vacuum chamber packaging machines for vacuum cooking mod.
calibration