9.4 PROGRAMMING AND OPERATION: VACUUM bAGS
gas function: for functional reasons, between the gas and vacuum parameters a minimum difference of
30% is always maintained.
Sealing function: the minimum value of the sealing parameter is equal to 1 second.
Proceed as follows:
1) Schedule the vacuum functions, additional vacuum, gas, sealing:
PhASE DESCRIPTION
1
Select one of the 20 user programs with the cursor keys UP/DOWN.
2
Select the function to be programmed with SEl.
3
Enter programming by pressing PROG.
4
Change the value by pressing the UP/DOWN cursor keys.
Confirm the value with PROG or access the next function to be programmed by
5
pressing SEl.
6
Proceed with other functions to be varied and confirm each time with the key
Resetting of the factory values Press at the same time the "STOP" and "UP" keys upon ignition.
The 99% values are thus reset for the vacuum function, 5 seconds of additional vacuum, gas input deactivated and 3.5
seconds of sealing on all 20 customisable programs.
3) lower the upper lid to start the cycle; to move earlier from one function to the next, press the SEl button. At the
end of the cycle, the lid opens automatically.
4) Interruption of the cycle: pressing the STOP button at any time, the machine immediately stops the cycle and the
chamber is decompressed.
9.4.1 NAMING CUSTOM USER PROGRAM
It's possible to assign to each user program (1 - 20) a name, consisting of up to 6 letters.
Proceed as follows:
PhASE DESCRIPTION
1
Select one of the 20 programs available.
2
Enter programming. (the first digit of the lower display starts to flash).
3
Select a letter.
4
Confirm the letter and access the next to be programmed.
5
Confirm.
Rev. 01 - 03/2018 - Cod. 1500024 - Instruction manual for vacuum chamber packaging machines for vacuum cooking mod.
OPERATION
KEy
KEy
Cuisson
47