INDUCEMENT STRATEGY
MRT 2150 Privilege Plus ST4 S2 / MRT 2550 Privilege Plus ST4 S2
Impacts and Actions by Operator
To ensure proper Tier 4 emission levels and to comply with the EPA and CARB regulations it has been implemented an inducement strategy
that will activate when emission related warnings occur. The following occurrences will trigger a warning indicator light:
• Low DEF Additive
• Insu cient DEF Additive Quality
• Faulty Elements of the Aftertreatment
In the case that inducement occurs again within 40 hours of engine operation, shortened inducement periods are activated.
Operators must:
- regularly check the gauge to make sure the DEF additive is at a proper level or
else engine inducement may occur;
- ensure in-time refi lling with DEF additive;
- avoid any contamination of DEF additive with any other fl uids or debris;
- ensure refi lls with properly stored DEF only.
INDICATORS AND DESCRIPTIONS OF THE INDUCEMENT STRATEGY EMISSIONS CONTROL SYSTEM OF THE EXHAUST GAS
Overview:
Indicator
Description
lamp
Diesel Exhaust Fluid
(DEF)
Torque Limiter Active
LIM
(LIM):
Engine Malfunction
Stop Engine Lamp
Buzzer
(*): In case of reoccurring failures the time for the fi nal inducement will be reduced from 240 to 30 minutes.
OPERATING RESTRICTIONS OF THE INDUCEMENT STRATEGY
Problem
Possible causes/consequences
An emissions-relevant malfunction
The indicator
in the exhaust gas aftertreatment
lamp lights up
system or in the DEF supply has
been detected.
The engine torque is limited to a
The indicator
maximum between <100% and
lamp lights up
> 50% across the whole engine
speed range.
The engine torque is limited to a
The indicator
maximum of ≤ 50% across the
lamp flashes
whole engine speed range.
The orange
A failure and tampering in the
indicator lamp
engine system has been detected
lights up
A serious fault in the engine
The red
system has been detected
indicator lamp
lights up
Level: ULTRA SEVERE
A serious fault in the engine
The indicator
system has been detected
lamp flashes
red.
Level: FINAL
With each transition of inducement state the buzzer
sounds for 5 seconds. In case of an override, the
buzzer sounds with a frequency of: 1 bpm.
EN
LOW: Maximum available torque is
reduced to 75% of peak torque across
the speed range and for a time interval
between 120 to 240 minutes.
SEVERE: Maximum available torque
will be reduced from 75 to 50% and for
a time interval between 240* a 265*
minutes.
Engine speed will be reduced to 60%
rated speed and for a time interval
between 240* a 265* minutes.
ULTRA
SEVERE: Maximum available torque
will be reduced from 50 to 20%, and
simultaneously engine speed will be
reduced to idle and for a time interval
between 265* a 290* minutes.
FINAL: The engine torque is limited to
a maximum of 20% across the whole
engine speed range and for a time
interval between 290* a 300* minutes.
The engine speed is limited to idling
speed and for a time interval between
290* a 300* minutes..
A maximum of 3 overrides for 30
minutes each is possible.
2-57
LEVEL:
consequences/times