Connection Assignment Of The I/O Signal Interface - Weber Legi-Air 2050 Traduccion De Las Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 343
Chapter 6 Installation and initial commissioning

Connection assignment of the I/O signal interface

Relay outputs: Capacity 1A 30 VDC / 0.5A, 125 VAC
(*) Output auxiliary voltage:
+ 24 VDC, max. 150 mA briefly
Trigger input: The input is universally usable for the connection of a switch contact, NPN or PNP photocell,
or PLC with active switching voltage.
Examples:
Trigger
PLC
+24V
Trigger
Version: 24.05.2016
A customer-specific wiring diagram which must be used first and
foremost is included in the system documentation. The standard
connection assignment of the interface is described below.
GND
GND
Do not use
Do not use
+24 VDC
+24 VDC
Do not use
Ready NO 1
Ready NC 1
Ready Com 1
Sync NO 1
Sync NC 1
Sync Com 1
Trigger
Trigger
Trigger
Trigger -
Fig. 6-4: Connection assignment of the I/O interface (external view)
Page 41 of 68
40037053 BTA Legi-Air 2050
GND
Trigger In -
Trigger In +
Reset
+24 VDC
Start
Ready NO 2
Ready NC 2
Ready Com 2
Sync NO 2
Sync NC 2
Sync Com 2
Photocell
Trigger
Trigger
PNP
DE
GB
FR
NL
Photocell
NPN
ML-GB

Publicidad