Weekly repair/maintenance (after approx. 40 operating hours)

Prerequisites
Labeller is separated from the voltage and compressed air
No product handling
Required equipment
Compressed air spray (*21800768)
Soft brush (round or flat approx. 10 mm)
* Product recommendation! Can be obtained from the Bluhm Weber Group using the 8-digit item number.
Instruction
How to perform the weekly repair/maintenance.
Step
1
2
3
4
5

Biannual repair/maintenance (after approx. 1000 operating hours)

Prerequisites
Labeller is separated from the voltage and compressed air
No product handling
Required equipment
Lithium saponified lubricant (Multemp lubricant PS2 by Kyodo Yushi Co.)
Instruction
How to perform the biannual repair/maintenance.
Step
1
2
Version: 24.05.2016
Approach
Observe the maintenance notices of the printer (see user manual).
Clean all the sensors (product sensor, var. stroke sensor) carefully with a
soft brush and compressed air spray.
Do not use the operational compressed air supply for this, since this is
sometimes insufficiently dry (oil/water residues). If the electronics come into
contact with moisture, this will lead to damages!
Check all hose connections for tight fit and possible leaks.
Remove any dust deposits from the system enclosure.
Check the mechanics of linear or swivel unit incl. the dispensing tamp for a
tight fit of all screws and connections.
Approach
Observe the maintenance notices of the printer (see user manual)
Clean and re-grease the guide rail of the applicator.