Chapter 6 Installation and initial commissioning
Quick reference >> DIP-Switch settings
The DIP-Switch position changes will only become effective after pressing the [re-
set] button.
[SW1]
OFF
ON
[SW2]
[SW3]
OFF
OFF
ON OFF
OFF
ON
ON
ON
[SW4]
OFF
ON
*Trigger impulse >> input signal (trigger) to the applicator interface, for example, from a photocell or conveying system.

DIP-Switch [SW1]

Activation of the pressure monitoring. If within 2 seconds after the *trigger
impulse no label feeding is performed by the print module, the labeller will
[SW1] = ON
switch to a timeout error (see chapter Troubleshooting). This setting is
only useful when the print data is individually transmitted (on-demand)
(comp. Print data management 29).
[SW1] = OFF Activates the function timeout monitoring.

DIP-Switch [SW2] + [SW3]

Configuration of the position in which the tamp pad waits until the *trigger impulse initiates
the application process. More specifically, it is the response of the print-application system
to the *trigger impulse.
*Trigger impulse will be ignored. If the print module has a sufficient num-
[SW2] = OFF
ber of print jobs, the Legi-Air 2050 (without external triggering) will perma-
[SW3] = OFF
nently conduct application cycles. Ideally, this configuration can be used
for service purposes and time optimizations.
[SW2] = ON
The labeller will begin to print the label after the *trigger impulse and then
immediately perform the application cycle.
[SW3] = OFF
The label was already printed and handed over to the tamp pad. If the
[SW2] = OFF
*trigger impulse is executed, the dispensing tamp will move and apply the
[SW3] = ON
label.
[SW2] = ON
The dispensing tamp will wait in the extended position with the label for
the *trigger impulse to blow-off the label (inverted Tamp Mode).
[SW3] = ON
*Trigger impulse >> input signal (trigger) to the applicator interface, for example, from a photocell or conveying system.
Version: 24.05.2016
Pressure monitoring (timeout 2 sec.)
Timeout deactivated
Timeout enabled
Labelling mode
*Trigger impulse is ignored (continuous print-application cycles)
starts the label printing. Application is carried out automatically afterwards
waiting for label at the tamp in the basic position, for the *trigger impulse
waiting extended with the label at the tamp for the *trigger impulse
Synchronization security
*Trigger impulses are ignored during the cycle
*Trigger impulses are generated during the cycle with a subsequent fault
message
Page 47 of 68