10 Attachment
Model
Terminal
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
4380
-, +1
+3
*1
For IP20 protection, use wires that are in the range of applicable gauges. If your installation does not need IP20 protection, smaller
cables can be used.
*2
Remove insulation from the ends of wires to expose the length of wire shown.
*3
Install an RCM/RCD with this wire gauge to maintain compliance with IEC/EN 61800-5-1.
*4
Terminals - and +1 have two screws. The Recommended Gauge is the wire gauge for one terminal.
376
Applicable Gauge
Recomm. Gauge
(IP20 Applicable Gauge
mm
2
95 - 150 × 2P
150 × 2P
(150 × 2P)
95 - 150 × 2P
150 × 2P
(150 × 2P)
120 - 185 × 2P
185 × 2P
(185 × 2P)
95 - 150 × 2P
150 × 2P
(150 × 2P)
95 - 240
120
YASKAWA TOMPYEULA7002A LA700 Series Installation and Operation Instruction
Wire Stripping
Length
*2
*1
)
mm
mm
2
-
-
-
-
-
(-)
Terminal Screw
Tightening Torque
Size and Shape
N∙m (lbf∙in)
35
M12
(310)
35
M12
(310)
35
M12
(310)
35
M12
(310)
32 - 40
M12
(283 - 354)