7
CPE Trunk Group (Grupo de troncales CPE)
Parte 2 de la página Trunk Group CPE
TRUNK FEATURES
ACA Assignment? n
Suppress # Outpulsing? n
Pantalla 7-44. Página Trunk Group CPE (Grupos de troncales CPE) (parte 2)
Página Administrable Timers
ADMINISTRABLE TIMERS
Incoming Disconnect(msec): 500
Incoming Dial Guard(msec): 70
Incoming Glare Guard(msec): 1500
Outgoing End of Dial(sec): 10
Programmed Dial Pause(msec): 1500
END TO END SIGNALING
Tone (msec): 350
OUTPULSING TIMING
PPS: 10
Pantalla 7-45. Página CPE Trunk Group Administrable Timers (Temporizadores
administrables del grupo de troncales CPE)
TRUNK GROUP
Measured: none
Data Restriction? n
TRUNK GROUP
Outgoing Rotary Dial Interdigit(msec): 800_
Incoming Incomplete Dial Alarm(sec): 255
Pause (msec): 150
Make (msec): 40
Maintenance Tests? y
Outgoing Disconnect(msec): 500
Outgoing Dial Guard(msec): 1600
Outgoing Glare Guard(msec): 1500
Outgoing Seizure Response(sec): 5
Disconnect Signal Error(sec): 240
Break (msec): 60