• POWER TRIM/TILT ASSEMBLY DOES NOT HOLD IN POSITION

Check the manual valve for tightness.
Tight
Check for oil leaking from the power trim/tilt
assembly.
Not leaking
Check the blow pressure (P. 14-36).
Normal
Check the oil level with the piston rod fully
extended (P. 14-35).
Normal
Check for air in the system.
No air in the system
Power trim/tilt assembly faulty.
Repair the faulty part by referring to the
QUICK REFERENCE CHART (P. 2-53).
2-51
Loose
Tighten the manual valve to the specified
torque.
TORQUE: 1.7 N . m (0.2 kgf . m, 1.3 lbf . ft)
Leaking
Replace the O-rings and/or oil seals at the
leaking points.
Abnormal
Replace the motor assembly or gear pump
assembly.
Low level
Add the oil up to the specified level
(P. 14-35).
Air in the system
Bleed air from the system (P. 14-35).