Descargar Imprimir esta página

Blackmagic Design ATEM 1 M/E Manual De Instalación Y Funcionamiento página 125

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 547
Using Blackmagic UltraScope
125
Waveform Display on Windows can show Luminance,
Composite or Both views.
Waveform Display
The Waveform Display is similar to traditional composite waveform monitors seen in many broadcast
studios. On Windows, select B/W for the luminance only view, COMP for the composite only view, and
BOTH for the twin luminance and composite view.
Select B/W for the luminance view which provides a digitally encoded waveform similar to traditional
luminance waveform monitors. The luminance view is very useful when adjusting luma (brightness) levels in
an image. Turn on the GAMUT function, and any illegal luma levels will be highlighted in bright red, so they
are easy to see. Instructions for setting luma limits can be found in the Error Logging Display section of this
manual. Traditional luminance waveform monitors only supported composite analog standard definition
video. However UltraScope's luminance view works in high definition as well as standard definition, so
you have a consistent and easy way to adjust luma levels even when monitoring high definition digital
video formats!
For Windows users, the composite view is exciting because it's a fully digitally encoded composite waveform
view and similar to a traditional waveform monitor. This provides a much easier way to align to test signals,
such as color bars, because you can use the composite waveform exactly the same way as it has always been
used. Composite view also works in high definition, so you have a consistent and traditional way to adjust
video even when working in high definition!
When BOTH view is selected on a Windows PC, the composite and luminance waveforms display side by
side in a twin view. This is incredibly useful when adjusting video levels or color correcting. It's impossible for
a vectorscope to show which objects in the video have color because a vectorscope just shows what colors
are in the whole image and not which objects have color. When color correcting, you often need to look for
specific parts of the image, remove the color and produce a neutral state. This is because the composite
waveform is the same as the luminance signal but with chroma added.
Choosing this twin view makes it easy to identify similar items in the luminance and composite waveforms,
and if more blur or chroma is observed in the composite area, the item has color. If some part of the
video image is neutral gray, then it should look the same on both waveforms because no chroma will
be present. With the twin view, you can look around the waveform and see the levels of color or chroma
of various objects. Now you can see if specific objects in the video image are color or black and white.
You can make technical and creative decisions using the Waveform Display.
When the Waveform display is zoomed in, you can toggle between COMP and B/W, and view the same
region of an image in the zoomed display.