6.2 Alarm Codes
Code
AL 001
AL 002
AL 003
AL 100
AL 101
AL 102
AL 103
EN
AL 104
AL 105
AL 200
AL 201
Generator safety cut-off
AL 202
AL 203
AL 300
AL 301
AL 302
AL 303
Communication error with Main Board
AL 304
AL 305
AL 306
AL 307
AL 308
AL 309
AL 310
AL 311
AL 401
Generator temperature low
AL 402
6.3 Messages
Code
Msg001
Standby or cycle start
Msg002
Standby or cycle start
Msg003
Pin entry
Msg004
Water loading
Msg005
Cycle start
Vacuum Test start
Msg008
Machine switch-on
Msg009
Machine switch-on
Msg010
Machine switch-on
Msg011
Machine switch-on
Msg012
Msg013
Incorrect date
Msg014
Do vacuum test
Msg016
PIN too short
Duplicate PIN
Msg017
Msg018
MB FW revision incompatible with CPU FW
72
Message
Reset pressed
Blackout
Water filling time
Chamber probe fault
Generator probe fault
Bandle probe fault
Pressure transducer
Door microswitch
Safety microswitch
Chamber safety cut-off
Bundle safety cut-off
Safety valve fault
Hardware error
Reboot the system
Valve drive voltage
Mains frequency error
Watchdog trip
Reboot system
Hardware error
Hardware error
Hardware error
Hardware error
Hardware error
Hardware error
Hardware error
Band temperature low
Phase
The reset button was pressed
A blackout has occurred
The time to fill the feed tank is too long
The chamber probe reading circuit is faulty
The generator probe reading circuit is faulty
The pipe bundle probe reading circuit is faulty
The pressure tansducer is faulty
The door microswitch has opened unexpectedly
The safety microswitch has opened unexpectedly
The chamber has exceeded the safety temperature
The generator has exceeded the safety temperature
The pipe bundle has exceeded the safety temperature
The pressure has exceeded the maximum trip threshold
of the safety valve
There is no synchronisation for managing AC loads and
checking the mains frequency
There is no valve drive voltage due to a PTC trip
The mains frequency is < 45 Hz or > 65 Hz
Program execution has crashed
There is a communication fault between the main board and
the CPU board
Hardware fault on the main board
Hardware fault on the main board
Hardware fault on the main board
Hardware fault on the main board
Hardware fault on the main board
Hardware fault on the main board
The cycle has incorrectly been closed – Software error
Generator failure
Band failure
Chamber temperature over limit
Serial number inconsistency between CPU and MB
Lubricate the automated system of the door
Replace the Bio-X filter
Conduct maintenance
System date incorrect - Check
Firmware version incompatible – contact Technical Support
Description
Message
Feed tank empty
Feed tank full
Incorrect Pin
Poor water quality
Door open
Do vacuum test
PIN too short
PIN already exists
Reset
procedure
A/B
A/B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A