02.02.09
CONVERSOR DE FREQUÊNCIA DOS SILOS, FILLER E FINOS
FILLER Y FINOS
FREQUENCY CONVERTER OF THE FILLER AND FINE AGGREGATE BINS
CONVERTISSEUR DE FRÉQUENCE DES TRÉMIES DE GRANULATS, FILLER ET FINES
(EN)
Diagnosis
The converter has a status LED that indicates if any operational failure occurs. The table below indicates the kind of
failure and its possible cause.
LED Color
LED Status
*
Off
Yellow
Constantly blinking
Yellow
Constant quick blinking Ready
Yellow
Steady light
Blinking with different
Green / Yellow
colors
Green
Steady light
Green
Constant quick blinking Active current limit
Red
Steady light
Blinks two times then
Red
pauses
Red
Blinking slowly
Blinks three times then
Red
pauses
Blinks four times then
Red
pauses
Blinks five times then
Red
pauses
Blinks six times then
Red
pauses
6 / 8
76179/0004
CONVERSOR DE FRECUENCIA DE LOS SILOS,
Fig. 7: Converter diagnosis
Operational status
Not ready
Not ready
Ready but the unit is
inhibited
Ready but with a timeout
error
Unit free
Not ready
Irregularity 07
Irregularity 08
Irregularity 90
Irregularity 17 to 24, 37
Irregularity 25, 94
Irregularity 01
Irregularity 11
Irregularity 84
Irregularity 89
Irregularity 06
Status LE
Description
No 24 V power supply.
Auto-test active or 24 V source present, but power
supply not OK.
Brake opening without release (only with S2/2 =
LIG).
24 V source and power supply OK, but no release
signal.
Cyclic data exchange with communication error.
Motor in operation.
The activation reached the current limit.
Check the 24 Vdc energy source.
Make sure that a dc signal with a low ripple level is
present (max. residual ripple) 13%).
Voltage too high in intermediate circuit.
Rotation monitoring error (only with S2/4 = LIG).
Selection of the incorrect motor-converter - MM03 -
DT71D4 ∆.
CPU error.
EEPROM error.
Over current at output stage.
High temperature at output stage.
Too high temperature in the motor. Incorrect motor-
converter selection.
Too high temperature on brakes Incorrect motor-
converter selection.
Lack of phase on network.
CC.15 / CC.17 / CC.19